Page 174 of 332 Chapter 13 — Installing and connecting the cross-connect terminal

3Attach labels on the cross-connect terminal to indicate the terminal blocks assigned to the following:

25-pair cables from the chassis

AUX wiring

Telephones and Attendant Consoles

Trunks

Analog line cards

DC5/AC15/RAN/PAG cards

Data Access cards

Power Failure Transfer Units

Digital line cards

Exchange line trunk cards

Direct Dialing Inward trunk cards

miscellaneous equipment

—————————— End of Procedure ——————————

Installing the Krone Test Jack Frame for the UK

The Krone Test Jack Frame provides terminating strips that hold 10 pairs of cable. Generally, only 8 of the 10 pairs are used. As a result, one 25-pair cable requires three terminating strips:

8 pairs/strip x 3 strips = 24 pairs

Figure 50 shows how one 25-pair cable is divided among three terminating strips on the Krone Test Jack Frame.

553-3021-209 Standard 3.00 April 2000

Page 174
Image 174