Page 254 of 332 Chapter 18 — Connecting the trunks

Connecting trunks without a PFTU

Procedure 39

Connecting trunks without a PFTU

1From the assignment record, determine the location of the trunk connection and its associated Terminal Number (TN) at the cross-connect terminal.

2With cross-connect wire, connect the trunk to the TN.

Make sure that the wiring is not reversed and is on the correct terminals.

Tables 57 to 59 list the connections for trunks. For trunk connections for Europe, see Tables 60 to 68. For trunk connections for the UK, see Tables 69 to 75.

—————————— End of Procedure ——————————

Connecting trunks with a PFTU

Procedure 40

Connecting trunks with a PFTU

1Locate the PFTU terminal blocks at the cross-connect terminal.

2Cross-connect the first pair of the assigned PFT to the telephone. See Table 56 on page 255 for PFTU connections.

3Cross-connect the second pair of the PFT to the TN assigned to the telephone.

4Cross-connect the third pair of the PFT to the central office trunk.

5Cross-connect the third pair of the PFT to the TN assigned to the trunk.

6Repeat for each trunk assigned to the PFTU.

—————————— End of Procedure ——————————

553-3021-209 Standard 3.00 April 2000