Page 56 of 332 Chapter 3 — System and site requirements

Table 11

AC input requirements for each NTDK91 and NTDK92 (North America)

Voltage

Recommended: 100-120 volts

Maximum limits: 90 and 132 volts

 

Single phase

 

 

Frequency

50-60 Hz

 

 

Power

550 VA maximum

(I/P max)

 

 

 

Outlet Type

120 volt, 15 Amp supply

 

 

Table 12

AC input requirements for each NTDK91 and NTDK92 (Europe and UK)

Voltage

Recommended: 208/220 volts

Maximum limits: 180 and 250 volts

 

Single phase

 

 

Frequency

50-60 Hz

 

 

Power

550 VA maximum

(I/P max)

 

 

 

Outlet Type

208/240 volt, 15 Amp supply

 

 

Note 1: As local power specifications vary, see a qualified local electrician when planning your power requirements.

Note 2: The Supplied power must be single-phase 240 or three-phase 208 Y, and must have a system ground conductor.