Page 236 of 332 Chapter 17 — Connecting the telephones

Procedure 33

Connecting an off-premise telephone

1Install the NTAK92AA Off-Premise Protection Module on the wall using four #10 1/2 in (minimum) screws.

2Connect a #6 AWG (#40 Metric Wire Gauge) from the grounding lug at the bottom of the NTAK92AA Off-Premise Protection Module to an earth ground. Refer to Figure 68 on page 237.

Note: In the UK, use a 2 mm2 (#6 AWG) ground lug. In Europe, use a #6 AWG (16 mm2) ground lug.

WARNING

If connecting to a message waiting line card, unseat the card from its assigned slot before continuing with the next step.

3Connect two NTAK9204 cables (one from connector J1 and one from connector J2) from the protection module to the cross-connect terminal.

Terminate the cables as shown in Figure 65 on page 231.

4Cross-connect the J1 cable to the Tip and Ring connections coming from the line card.

Table 52 on page 242 provides the default DN assignments.

5Cross-connect the J2 cable to the off-premise telephone.

6Install the regulatory label provided with the Off-Premise Protection Module on the inside right-hand wall of the chassis.

7Install the line card in its assigned position.

Now, you can activate the telephone, as described on page 244.

—————————— End of Procedure ——————————

Connecting an Attendant Console

Procedure 34

Connecting Attendant Console

1Locate the Attendant Console terminations at the cross-connect terminal.

2Locate the line card terminations at the cross-connect terminal.