Chapter 4 — Creating an equipment layout plan and a card slot assignment plan Page 79 of 332

Table 18

Card slot assignment plan (Continued)

Card

Card slot

Number of

cards

 

 

 

 

 

NT8D16 Digitone Receiver

 

 

 

 

 

NT8D15 E&M Trunk

 

 

 

 

 

NT7D16 Data Access

 

 

 

 

 

NT6D70 SILC (See Note 1)

 

 

 

 

 

NT6D71 UILC

 

 

 

 

 

NT5K02 XFALC

 

 

 

 

 

NT5K18 XFCOT

 

 

 

 

 

NT5K17 XDDI

 

 

 

 

 

NT5K19 XFEM

 

 

 

 

 

NT5K36 XDID/DOD

 

 

 

 

 

NT5K21 XMFC/MFE

 

 

 

 

 

NTAG26 XMFR

 

 

 

 

 

Note 1: Install the NT6D70 SILC card in the Main Chassis (Slots 1, 2, or 3) if it is used as a clock controller.

CAUTION

If you use NE-A25B cables instead of NTAK19AA and NTAK19BA cables with the NTAK02 and NTAK03 cards, continue with caution. NE-A25B cables are not wired out to station equipment or trunk circuits. NE-A25B cables can only be wired out to SDI circuits.

Make sure to first allocate the cards that you must install in the Main Chassis. Fill the remaining card slots as required.

If you plan on using the preassigned numbering plan with consecutive numbers, make sure you assign all line cards in consecutive card slots.

Option 11C Mini Planning and Installation Guide

Page 79