Page 320 of 332 Appendix B – Changing preprogrammed data

Example:

The first number in the numbering plan is 2200. For the first number in the numbering plan to be 2300, and the first line card is in slot 6, perform the following calculation:

1Locate the first line card. Subtract 1 from the number of the card slot that it is in.

6 - 1 = 5

2Multiply the number from step 1 by 16:

5 X 16 = 80

3Subtract this number from the first number in the numbering plan:

2300 - 80 = 2220

4Enter this value in response to the “FIRST NUMBER (2200)?” prompt on the administration telephone:

FIRST NUMBER (2000)? 2220

Removing numbering plan conflicts

This section contains methods for removing any numbering plan conflicts that occur.

Conflicts with Meridian Mail Mini data

Manufacturers and distributors ship the Option 11C Mini system with data already programmed to support Meridian Mail Mini. The Meridian Mail Mini preprogrammed data can cause problems in the following situations:

there is a numbering plan conflict with preprogrammed Meridian Mail Mini data and the programming required for another feature

another circuit card requires card slot 10

553-3021-209 Standard 3.00 April 2000

Page 320