Chapter 12 — Installing the circuit cards

Page 165 of 332

 

 

Table 33 provides OPS analog line card configuration information.

Table 33

OPS analog line card configuration

 

Application

On-premise station (ONS)

Off-premise station (OPS)

 

 

 

 

 

 

 

 

 

 

 

 

 

Class of service

 

 

ONS

 

 

 

OPS

 

 

(Note 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop resistance

 

0 - 460 ohms

 

 

 

0 - 2300 ohms

 

 

 

 

 

 

 

 

Jumper strap

Both JX. 0 and JX.1 off

Both JX. 0 and JX.

Both JX. 0 and JX.

 

setting

 

 

 

 

 

 

1 off

1 on

 

(See Note 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop loss dB

0-1.5

 

>1.5-2.5

 

2.5-3.0

0-1.5

 

1.5-2.5

2.5-3.0

4.5-15

 

(See Note 3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIMP

600¾

 

600¾

 

600¾

600¾

 

600¾

600¾

600¾

 

(See Notes 1, 4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIMP

600¾

 

3COM1

 

3COM2

600¾

 

3COM1

3COM2

3COM2

 

(See Notes 1, 4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gain treatment

 

 

 

 

No

 

 

 

 

Yes

 

(See Note 5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: Configured in the Single line Telephone Administration program (LD 10).

Note 2: The maximum signaling range supported by the OPS analog line card is 2300 ohms.

Note 3: Loss of untreated (no gain devices) metallic line facility. Upper loss limits correspond to loop resistance ranges for 26 AWG wire.

Note 4: Default software impedance settings are:

ONS CLSOPS CLS

TIMP: 600 ohms 600 ohms

BIMP: 600 ohms 3COM2

Note 5: Gain treatment, such as a voice frequency repeater (VFR), is required to limit the actual OPS loop loss to 4.5 dB, maximum. VFR treatment of metallic loops having untreated loss greater than 15dB (equivalent to a maximum signaling range of 2300 ohms on 26 AWG wire) is not recommended.

Note 6: Jumper strap settings JX> 0 and JX. 1 apply to all eight units; “X” indicates the unit number, 0-7. “OFF” indicates that a jumper strap is not installed across both pins on a jumper block. Store straps that are not in use on the OPS analog line card by installing them on a single jumper pin as shown in Figure 46.