Page 280 of 332 Chapter 19 — Connecting an external alarm

3Use LD 15 and make the following changes.

Note: The following list only contains the prompts requiring a response. Use a Carriage Return, <CR>, to accept the default values for the other prompts.

a)Enter CHG in response to the REQ prompt.

b)Enter CDB in response to the TYPE prompt.

c)Enter the customer number (0-99) in response to the CUST prompt.

d)Enter the DN of the line assigned as an alarm port in response to the ALDN prompt.

Note: If the DN assigned to the alarm is accidentally called, the alarm activates. To avoid false alarms, make sure the DN is not consistent with the assigned numbering.

e)Press return in response to the remaining prompts.

—————————— End of Procedure ——————————

Alarm through a QUA6 PFTU

A QUA6 PFTU can be used to connect an external alarm through normally open or normally closed contacts of one of its units. The contacts operate under the same conditions as the PFTU, and can support the capacities listed in Table 76.

Table 76

AC capacities

 

AC capacities

 

 

Maximum switching power

50.0 V A.

Maximum switching voltage

125.0 V rms

Maximum switching current

0.5 A

 

 

Figure 70 on page 281 shows an example of the contacts on one unit (PFT1) of the PFTU. Figure 70 shows the contacts in normal operating mode, not in failure mode. Table 77 on page 282 provides the connections for all units on the PFTU.

553-3021-209 Standard 3.00 April 2000

Page 280
Image 280