Page 268 of 332 Chapter 18 — Connecting the trunks

Table 69

NT5K17 DDI cross-connect terminations (Continued)

Pair

Pins

Pair color

Unit number

 

 

 

 

T6

38

BK-G

 

R6

13

G-BK

Unit 6

 

39

BK-BR

 

 

14

BR-BK

 

 

 

 

 

T7

40

BK-S

 

R7

15

S-BK

Unit 7

 

41

Y-BL

 

 

16

BL-Y

 

 

 

 

 

NT5K18 Exchange line trunk card terminations

Cross connect the NT5K18 Exchange line trunk card as shown in Table 70.

Note: The connections on the NT5K18 Exchange line trunk card are polarity sensitive. Make sure the ground side of the trunk is connected to the A leg of the NT5K18 circuit. Make sure the -50 volt side of the trunk is connected to the B leg of the NT5K18 circuit.

Table 70

NT5K18 Exchange line trunk card cross-connect terminations

Pair

Pins

Pair color

Unit number

 

 

 

 

T0

26

W-BL

 

R0

1

BL-W

Unit 0

 

27

W-O

 

 

2

O-W

 

 

 

 

 

T1

28

W-G

 

R1

3

G-W

Unit 1

 

29

W-BR

 

 

4

BR-W

 

 

 

 

 

T2

30

W-S

 

R2

5

S-W

Unit 2

 

31

R-BL

 

 

6

BL-R

 

 

 

 

 

553-3021-209 Standard 3.00 April 2000

Page 268
Image 268
Nortel Networks Option 11C Mini manual NT5K18 Exchange line trunk card terminations