Page 72 of 332 Chapter 4 — Creating an equipment layout plan and a card slot assignment plan

Figure 10

Typical layout for installing the chassis on a wall in a vertical position

Leave at least

12 in. (305 mm) between edge of backboard and corner of room to allow for card insertion

Spacing is

21 in. (530 mm)

Allow 24 in. (610 mm) at the top for miscellaneous equipment

Draw horizontal line for bottom hole of wall mount bracket

Main

Chassis

Distance from edge of backboard to

isolated ground outlet 0 - 27 in. (686 mm)

Chassis

Expander

12 in. (305 mm)

10 inches

(254 mm)Each chassis measures

8.4 in. x 17.2 in. x 12.8 in.

(213 mm x 437 mm x 325 mm)

Recommended lowest position for chassis installation is

10 inches (254 mm) from floor

553-9035

Note: Leave wall space for the cross-connect terminal.