Chapter 4 Emulation Menu

P-Series XQ Emulation

Printer

Protocol

(from page 86)

P-Series

XQ

Control Code

06

6.0LPI

8.0LPI*

10.3LPI

Define CR

Code

CR = CR* CR = CR + LF

Auto LF

Disable*

Enable

 

Define LF

 

Compressed

 

 

Code

 

Print

 

 

 

 

 

 

 

LF = CR + LF*

 

char 01 SOH*

 

 

LF = LF

 

char 03 ETX

 

 

 

 

char 09 HT

 

* = Factory Default

Elong/Alt.

Font

Elng=BS Font=SO* Elng=SO Font=BS

HS Print

char 02 STX* char 03 ETX char 09 HT

EVFU Select

Enable*

Disable

Upr. Case

Select

Disable*

Enable

Slew

Relative

1 to 16 lines*

1 to 15 lines

Control Code 06

Control Code 06 defines the function of ASCII code hex 06 (ACK). You can select an alternate line spacing of 6, 8, or 10.3 LPI.

Define CR Code

This option controls the action of the printer when it receives a Carriage Return code (hex 0D) from the host computer. If this feature is enabled, each time the printer receives a Carriage Return, it inserts an additional Line Feed code (hex 0A) into the data stream. Do not use this feature if the host computer sends Line Feeds to the printer.

CR = CR. Does not insert an extra Line Feed after each Carriage Return.

CR = CR + LF. Inserts an extra Line Feed after each Carriage Return. The next print position will be print position 1 of the next line.

Auto LF

This option defines the printer action when print data is received past the forms width setting.

Disable. Discards any data past the forms width.

Enable. Performs an automatic carriage return and line feed when data is received past the forms width.

100

Page 100
Image 100
Printronix P5000LJ user manual Series XQ Emulation, Control Code