Chapter 4 Emulation Menu

Offpage Errors

Disable. Does not report errors for elements that start or end beyond the right edge of the page.

Enable. Reports errors for elements that start or end beyond the right edge of the page.

Barcode Errors

Enable. An error message will print when invalid bar code data is encountered.

Disable. Code V will not print an error for illegal bar code data; the bar code will be skipped.

Note

When Barcode Errors is disabled, the Code V emulation will try to make

 

the best use of invalid data by either truncating extra digits or adding zeros

 

to the end of bar code data to meet minimum data length requirements for

 

some bar codes. Not all errors will be corrected.

 

 

Ignore / DB8 Setup

Following are several options which define character filtering and data bit 8.

Ignore Nulls

Disable. None of the null characters (hex 00 or 80) are ignored.

Enable. Null characters are filtered out of the data stream.

Data Bit 8

Enable. The PI line is not passed directly from host to printer; all 8 bits are used for data bits, and characters in the hex 80-FF range can be accessed.

Disable. When the host PI line is enabled, data bit 8 internally indicates PI line status. To use the PI line, disable data bit 8 and enable the Host PI configuration option (under the PI Control option, below).

Note

Data bit 8 is interpreted as either data bit 8 or the PI signal, but never both.

 

When enabled as data bit 8, data bit 8 has priority over the PI signal, and

 

all data above hex 7F is used to access character data and not to interpret

 

PI line data.

 

Conversely, when data bit 8 is disabled and the PI signal is used, data bit 8

 

of the data is reserved for use as the PI function, and you cannot access

 

characters in the hex 80-FF range. Therefore, to access characters in the

 

hex 80-FF range, data bit 8 must be enabled.

 

 

112

Page 112
Image 112
Printronix P5000LJ user manual Ignore / DB8 Setup, Offpage Errors