IGP/PGL Emulation

Ext Execute Copy

Disable. Dynamic data, overlay data, etc. are not allowed if the optional Form Count parameter (number of forms to print) is specified as part of the Execute command. (This setting is IGP-100 compatible.)

Enable. Dynamic data, overlay data, etc. are allowed within a form in which the Form Count parameter is specified in the Execute command. In this case, the exact same form (with identical dynamic data) is printed for whatever the Form Count is. However, incremental data is not incremented since the page that is printing is exactly the same, the overlay data is only printed with the first form and not on subsequent forms, and each form is printed on a separate page.

UPC Descenders

This parameter allows you to print bar code descenders when human readable data is not presented in the UPC/EAN bar codes.

Enable. UPC/EAN bar codes are printed with descenders, even if there is no human readable data.

Disable. UPC/EAN bar codes are printed without descenders if there is no human readable data.

Compressed CPI

This parameter allows you to choose a compressed character (60% shorter) for 17 or 20 CPI instead of the normal height character.

Disable. The PGL does not use compressed 17 or 20 CPI font.

Enable. Uses the standard compressed 17 or 20 CPI font.

Ignore Char

Ignore Mode

This parameter instructs the PGL to ignore the character selected under the Select Character menu.

Disable. The PGL does not ignore any characters.

Enable. The PGL ignores the characters specified in the Select Character menu.

Select Character

Instructs the PGL which decimal character (0-255) to ignore from the host.