4

Table 4-2

3800E Alarm Descriptions

 

 

ALARM

DESCRIPTION

 

 

DTE Loss

The signal indicating DTE presence has

 

been lost.

 

 

DTR On

The V.35 DTR signals is present.

 

 

RTS On

The V.35 RTS signal is present.

 

 

RLB On

The V.35 DTE Remote Loopback signal has

 

been set.

 

 

LT On

The V.35 LT signal is present.

 

 

TA On

The HSSI TA signal is present.

 

 

LA On

The HSSI LA signal is present.

 

 

LB On

The HSSI LB signal is present.

 

 

DSR On

The V.35 DSR is asserted.

 

 

CTS On

The V.35 CTS signal is asserted.

 

 

RLSD On

The V.35 RLSD signal is asserted.

 

 

TM On

The V.35 TM signal is asserted.

 

 

CA On

The HSSI CA signal is asserted.

 

 

LC On

Not used

 

 

Line crossed

E1 network lines are crossed.

 

 

Terminal Interface