4

DIGITAL LINK DL3800E

SR 3.00.22 NODE

1:

08/27/00 00:54:47 MAJOR

SELECTED DEVICE ADDRESS:

1.00.000

NAME:

 

 

UNIT CONFIGURATION

Exit Confirm

 

 

 

DATE: 08/27/00

 

 

 

 

 

 

TIME: 00:54:38

 

 

 

 

 

 

ALARM ENABLE: Disabled

 

 

 

 

 

AUTOMATIC BACKUP: 5 minutes after a database change.

 

FRONT PANEL: On

 

 

 

 

 

 

PERMIT SELECT DEVICE ACCESS FROM REMOTE:

No

 

UNIT NUMBER:

1

 

 

 

 

 

UNIT NAME:

 

 

 

 

 

 

SOFT SERIAL #: 1389031127991

 

 

 

HARDWARE REVISION: H

 

SOFTWARE REVISION:

3.00.22

(DOWNLOADED)

MIB REVISION: 1.10 January 10 2000

 

 

 

TERMINAL BAUD RATE:

 

9600

 

 

 

TERMINAL #BITS AND PARITY: 8 bits, No parity

 

 

TERMINAL STOP BITS:

 

2 bits

 

 

 

Figure 4-8 UNIT CONFIGURATION MENU

 

 

Table 4-5 Node Configuration Options

 

 

Option

Action

 

 

Date

Move the highlight bar to Date, and enter a valid date with the format

 

MM/DD/YY, and press the Enter key.

 

MM

1-12 month

 

DD

1-31 date

 

YY:

0-99 year

 

 

Time

Move the highlight bar to Time, and enter a valid time with the format

 

hh:mm:ss, and press the Enter key.

 

HH

0-23 hours

 

MM 0-59 minutes

 

SS

0-59 seconds

 

 

Alarm Enable

This option allows you to ENABLE or DISABLE the DL3800E unit External

 

Alarms. Highlight ALARM ENABLE and, using the space bar, toggle

 

between ENABLED and DISABLED until the desired choice appears.

 

 

Automatic Backup

This feature allows you to backup the database to the EEPROM

 

automatically, at certain intervals, or manually. To change the present

 

backup mode, highlight Automatic Backup, and use the Space Bar to toggle

 

between the following choices: after every database change, 15 seconds,

 

30 seconds, 1 minute, five minutes after each change, or Off (must change

 

manually with Save Configuration).

 

 

 

4-18

DL3800E Inverse Multiplexer User’s Guide — July 9, 2001

Page 58