Parameter | Description/Action |
|
|
TSLOT16 | Allows you to select between DATA and FLAG. If DATA is selected, timeslot |
| 16 will be used for payload data. If FLAG is selected, timeslot 16 will not be |
| used for payload and will be stuffed with the value 7E hex. |
| NOTE: E1 links are not truly independent. This field is selectable on a per- |
| E1 link basis. When the DL3800E unit treats the set of E1 links as a whole. |
| If only one E1 link is selected for FLAG, then the DTE bandwidth is reduced |
| to an amount corresponding to all links having been set for a time slot loss. |
|
|
Primary Clock Source | This allows you to select either the Primary Clock Source, transmit (xmt), and |
| receive (rcv) for the individual E1 network ports. |
| To change the present Primary Clock Source, use the UP and DOWN |
| ARROW keys to highlight either Xmt or Rcv on the Primary Clock Source |
| line, and use the Space Bar to toggle between the choices. For Xmt |
| (transmit) the choices are Network (NET), External (EXT), and Internal (INT). |
| For Rcv (receive) the choices are |
| E1 network ports), or Auto (the unit selects the best source). |
| The DL3800E unit can use several sources to generate the transmit clock. |
| The Internal selection uses an oscillator within the DL3800E, the Network |
| setting recovers the clock from the selected E1 line, and the External setting |
| recovers the clock from the |
| the unit. Typically, the clock source on one side of the link is set to Internal, |
| and the other is set to Network. (Default - Smt: Int., Rcv: Net 1) |
|
|
Secondary Clock Source | This allows you to select either the Secondary Clock Source, transmit (xmt), |
| and receive (rcv) for the individual E1 network ports. |
| To change the present Secondary Clock Source, use the UP and DOWN |
| ARROW keys to highlight either Xmt or Rcv on the Secondary Clock Source |
| line, and use the Space Bar to toggle between the choices. For Xmt |
| (transmit), the choices are Network (NET), External (EXT), and Internal (INT). |
| For Rcv, the choices are |
| network ports) or Auto (the unit selects the best source) until the desired |
| choice appears. (Default - Xmt: Int, Rcv: Net2) |
|
|
DSU Mode | This allows youyou to set the DL3800E unit up as a DSU, with one DTE, and |
| one Network port. |
| To change the present DSU Mode level, use the UP and DOWN ARROW |
| keys to highlight the DSU Mode item, and use the Space Bar to toggle |
| between the following selections until the desired choice appears: Inverse |
| MUX (standard operation) or Single E1 DSU. Highlight Confirm, and press |
| the Enter key to confirm the change. |
|
|