Table 4-7 NETWORK CONFIGURATION MENU Options (Continued)

 

 

Parameter

Description/Action

 

 

TSLOT16

Allows you to select between DATA and FLAG. If DATA is selected, timeslot

 

16 will be used for payload data. If FLAG is selected, timeslot 16 will not be

 

used for payload and will be stuffed with the value 7E hex.

 

NOTE: E1 links are not truly independent. This field is selectable on a per-

 

E1 link basis. When the DL3800E unit treats the set of E1 links as a whole.

 

If only one E1 link is selected for FLAG, then the DTE bandwidth is reduced

 

to an amount corresponding to all links having been set for a time slot loss.

 

 

Primary Clock Source

This allows you to select either the Primary Clock Source, transmit (xmt), and

 

receive (rcv) for the individual E1 network ports.

 

To change the present Primary Clock Source, use the UP and DOWN

 

ARROW keys to highlight either Xmt or Rcv on the Primary Clock Source

 

line, and use the Space Bar to toggle between the choices. For Xmt

 

(transmit) the choices are Network (NET), External (EXT), and Internal (INT).

 

For Rcv (receive) the choices are Net-1 through Net 8 (each of the individual

 

E1 network ports), or Auto (the unit selects the best source).

 

The DL3800E unit can use several sources to generate the transmit clock.

 

The Internal selection uses an oscillator within the DL3800E, the Network

 

setting recovers the clock from the selected E1 line, and the External setting

 

recovers the clock from the dB-9 Ext. Clock connector on the rear panel of

 

the unit. Typically, the clock source on one side of the link is set to Internal,

 

and the other is set to Network. (Default - Smt: Int., Rcv: Net 1)

 

 

Secondary Clock Source

This allows you to select either the Secondary Clock Source, transmit (xmt),

 

and receive (rcv) for the individual E1 network ports.

 

To change the present Secondary Clock Source, use the UP and DOWN

 

ARROW keys to highlight either Xmt or Rcv on the Secondary Clock Source

 

line, and use the Space Bar to toggle between the choices. For Xmt

 

(transmit), the choices are Network (NET), External (EXT), and Internal (INT).

 

For Rcv, the choices are Net-1 through Net 8 (each of the individual E1

 

network ports) or Auto (the unit selects the best source) until the desired

 

choice appears. (Default - Xmt: Int, Rcv: Net2)

 

 

DSU Mode

This allows youyou to set the DL3800E unit up as a DSU, with one DTE, and

 

one Network port.

 

To change the present DSU Mode level, use the UP and DOWN ARROW

 

keys to highlight the DSU Mode item, and use the Space Bar to toggle

 

between the following selections until the desired choice appears: Inverse

 

MUX (standard operation) or Single E1 DSU. Highlight Confirm, and press

 

the Enter key to confirm the change. (Default-Inverse Mux)

 

 

Terminal Interface

4-27