7

waveform monitor to the WF A OUTPUT loop connector

on the VCS-700 which is the last unit in the series

connection.

k WF B OUTPUT (waveform monitor B output) connector (BNC type)

Supplies the same video signal for a waveform monitor as the WF A OUTPUT connector. The signal loss of a connecting cable up to 100 meters (330 feet) long can be compensated for with the switch on the internal board. When you connect a waveform monitor using a long connecting cable, connect it to this connector. When using two or more VCS-700 units connected in series, connect a waveform monitor to the PIX B OUTPUT connector on the VCS-700 whose WF A OUTPUT loop connector is not used for series connection. For details on cable compensation, refer to the system manual.

l WF MODE (waveform monitor mode) connector (4-pin)

Connect to a corresponding connector on a waveform monitor to view the signals in sequential mode. This

connector supplies a staircase signal and sequential ON/OFF control signal.

mREMOTE connector (8-pin)

Connect a CNU-700 Camera Command Network Unit using a CCA-5 cable.

nI/O PORT (remote control) connector (D-sub 37- pin)

Accepts and supplies external control signals. You can select the signals output to a picture monitor and a waveform monitor with an external video selector connected to this connector. The selected input connector number is supplied from this connector.

o~AC IN (AC power input) connector

Connect to an AC power source using the supplied AC power cord. The power cord can be fixed to the VCS- 700 using the supplied plug holder.

7-8.MSU-700A, Master Setup Unit

7-8-1Operation Panel

5CLOSE button

4Signal output select buttons

3VF PW button

2CAM PW button

1ALL button

6STANDARD button

7AUTO SETUP block

8Camera/CCU function ON/OFF buttons

9Scene file control block

q; Menu operation block

qa IC card insertion block

qs PICTURE MONITOR buttons qd WAVEFORM MONITOR buttons

qf Camera select block qg Filter control block

 

 

 

 

 

 

 

 

AUTO SETUP

 

 

ALL CAM PW

VF PW

TEST1

TEST2

BARS CLOSE STANDARD

 

SKIN DTL

LEVEL

START/

WHITE

BLACK

 

AUTO HUE

 

BREAK

 

 

 

 

KNEE

DETAIL

LVLDEP GAMMA CHROMA MATRIX

 

 

 

 

 

 

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

KNEE

KNEE

 

 

 

 

 

MONO

COLOR

 

 

 

 

APARTURE SAT

 

 

 

 

 

COLOR CORRECT

 

 

 

 

5600K

AUTO

SKIN

DETAIL

SATURATION CONTRAST BLACK

CHARACTER

 

 

 

 

 

KNEE

DETAIL

GATE

 

 

GAMMA

 

 

 

 

 

 

1

2

3

4

5

 

 

 

 

 

 

 

 

 

SCENE FILES

 

 

 

STORE

 

 

 

 

 

ECS

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

ACCESS

 

 

ECS/SHUTTER

 

GAMMA

MASTER GAIN

R

G

B

 

ENC

 

 

1

2

 

3

4

5

 

PICTURE MONITOR

 

 

FILTER CTRL

 

 

 

ND

 

 

R

G

B

SEQ

ENC

 

 

A

B

 

C

D

E

 

WAVEFORM MONITOR

 

 

 

 

 

 

CC

 

 

PARA MULTI

TALLY

PANEL

ACTIVE

1

2

3

4

5

6

7

8

9

10

11

12

EXPAND

MODE

MULTI

CARD

CONFIGURATION

MAINTENANCE

FILE

PAINT

 

MASTER BLACK

IRIS

 

EXT

IRIS/MB

AUTO

ACTIVE

 

CALL

wa Iris control block

w; Camera number/ tally indication window

ql CALL button

qk MASTER BLACK control block

qj IRIS/MB ACTIVE button

qh ECS/Shutter control block (left) Gamma control block (center) Master gain control block (right)

aALL button

Press the button so it starts flashing to activate the 13 buttons located at the right (from CAM PW to AUTO SETUP) for all the connected cameras of the same group.

bCAM PW (camera power) button

Press and light up this button to turn the power supply to the video camera ON. (The button promptly flashes until the camera becomes ready for transmission.)

HDC-900/950/930 Series Product Information Manual

Chapter 7 Location and Function of Parts and Controls 106

Page 106
Image 106
Sony 950, 930, 900 manual MSU-700A, Master Setup Unit, 1Operation Panel