6

5. Enter the security code using the numeric keys,

then press

.

 

 

Note

[OK]

 

 

 

Each digit you input will be displayed as an

 

asterisk. The Security Menu items now appear.

 

 

 

 

 

 

 

 

 

Security Menu

Exit

 

 

 

 

 

 

 

 

 

Engineer Mode

 

 

Status Code

Change

Engineer Mode

6.Press [Status]. The display changes to the Security Status setting display.

 

Security Status

Exit

 

Engineer Mode

 

Ref.

Lens

OHB

 

Enable

Enable

Enable

 

 

Engineer Mode

 

Full Lock

View

Paint

 

Mode

Only

 

 

 

Operation

Proceed as follows:

Configuration Menu

MODE

 

 

 

Configuration Menu

 

 

Camera

CCU

 

MULTI

CNU

MSU

 

 

1

CARD

 

2

CONFIGURATION

 

 

MAINTENANCE

FILE

PAINT

(Example:MSU-700A)

1.Press to light the CONFIG button on the menu control block to call the Configuration menu on the display.

2.Press [CNU].

The CNU Configuration menu appears.

CNU Configuration menu

CNU Configuration Exit

Engineer Mode

RCP MSU

Assign Assign

7.Setting the status for control from the MSU-700A/ 750.

[Ref. Enable]: Set it to inverse video to enable the setting in the reference file (Factory setting: ON).

[Lens Enable]: Set it to inverse video to enable the setting in the lens file (Factory setting: ON).

[OHB Enable]: Set it to inverse video to enable the setting in the OHB file (Factory setting: ON).

[Full Lock]: Set it to inverse video to fully disable the MSU-700A/750 (Factory setting: OFF)

[View Mode]: Set it to inverse video to disable all operations from the MSU-700A/750 other than data reference (Factory setting: OFF). (Only the display and indicators will be active. Any setting and adjustment will be disabled.)

[Paint Only]: Set it to inverse video to enable the paint control only (Factory setting: OFF).

8.When the status settings are completed, press [Exit].

The Security menu display in step 5 is restored.

9.Press [Engineer Mode] to exit the Engineer Mode. The statuses specified in step 7 become valid.

Note

All operations are enabled in the Engineer Mode regardless of the above status settings.

Note

The item [MSU Assign] is displayed only when the Engineer Mode is active.

3.Press [MSU Assign].

The MSU Assignment menu now appears. Simultaneously, the character display of the CNU- 700 changes to the MSU Assignment mode. Using the four arrow buttons on the MSU Assignment menu (MSU-700A/750), move the cursor on the character display of the CNU-700 to the point where you wish to change the assignment.

MSU Assignment menu

MSU Assignment Exit

Set

Cancel

6-3-3MSU Assignment

You can assign specific units among the cameras in

Default

the same system to be selected or controlled from the MSU-700A/750. The MSU assignment is to be made, for example, to assign cameras to each MSU-700A/

750when multiple MSU-700A/750 units are used in the same system. This assignment operation is enabled in the Engineer Mode. Turn on the CONFIG/MSU/ SECURITY/ENGINEER Mode to activate the Engineer Mode.

HDC-900/950/930 Series Product Information Manual

Chapter 6 A Quick Lesson on Camera Settings 71

Page 71
Image 71
Sony 900 3MSU Assignment, Each digit you input will be displayed as an, Setting the status for control from the MSU-700A