7

c ND filter selector

 

When the FILTER LOCAL button is lit up, this selector

may be used to select an ND filter.

 

Selector position

Selected filter

 

 

 

 

1

Clear

 

 

 

 

2

1/4ND

 

 

 

 

3

1/8ND

 

 

 

 

4

1/16ND

 

 

 

 

5

1/64ND

 

 

 

dCC (color temperature conversion) filter selector

When the FILTER LOCAL button is lit up, this selector may be used to select a color temperature conversion filter appropriate to the light source illuminating the subject.

Selector position

Selected filter

 

 

A

Cross filter

 

 

B

3200K (clear)

 

 

C

4300K

 

 

D

6300K

 

 

E

8000K

 

 

eFILTER LOCAL (filter local control) button Pressing this button enables selection of a color temperature conversion filter or ND filter using the CC filter selector and ND filter selector. Pressing the button again gives control of the filters to the MSU- 700A/750 Master Setup Unit or RCP-700 series Remote Control Panel.

fUP TALLY switch

Set whether or not the camera’s Up Tally lamp and the lens’ tally lamp will light when the camera receives a red tally signal.

ON: The tally lamps will light.

OFF: The tally lamps will not light.

gVF (viewfinder) SCAN switch

Used to control the viewfinder screen display.

16:9: To set the viewfinder display to 16:9 aspect ratio.

4:3: To set the viewfinder display to 4:3 aspect ratio.

hSCREEN SIZE MARKER switch

Used to control the display of the screen size marker as follows:

ON ( ): Areas outside the specified ratio area will be darkened.

ON ( ): The screen size marker (white lines) will be displayed.

OFF: The screen size marker will not be displayed.

iCENTER MARKER switch

Used to control the display of the center marker as follows:

ON: A marker indicating the center of the picture area will be displayed on the viewfinder screen. The position of the center marker may be adjusted for the lens being used. The adjusted position may be stored in a lens file.

OFF: The center marker will not be displayed.

jSAFETY ZONE switch

Used to control the display of the safety zone marker as follows:

ON: A frame marking 90% of the picture area (the safety zone) will be displayed on the viewfinder screen. Using the Marker Settings page in the

Operation menu, the size of the displayed frame may also be set to 80%, 92.5%, or 95% of the picture area.

OFF: The safety zone will not be displayed.

kDISPLAY switch

The functions of the DISPLAY switch are as follows: ON: Text and messages describing the camera

settings and operating status may be displayed on the viewfinder screen.

OFF: Status messages will not appear on the viewfinder screen.

MENU: Menus for camera settings will be displayed on the viewfinder screen.

lMENU SELECT switch

The functions of the MENU SELECT switch are as follows:

ENTER: Confirm the menu or page selected using the MENU SELECT control, or confirm setting values.

CANCEL: Cancel menu setting values or return to page select mode or the top menu.

mMENU SELECT control

Used to select menu items or change setting values in the menus displayed on the viewfinder screen.

nAssignable switch

You can assign a function, such as lens extender ON/ OFF, using the OPERATION menu.

oVF DETAIL (viewfinder detail adjustment) switch ON: Emphasizes the contours of the image on the

viewfinder screen. When the switch is set to this position, you can adjust the amount of detail using the VF DETAIL control.

OFF: Disables contour emphasis.

pVF DETAIL (viewfinder detail) control Adjust the amount of detail of the picture on the viewfinder screen when the VF DETAIL switch is set to ON. This has no effect on the output signal of the camera.

Note

The viewfinder detail control function has no effect on a return video signal.

qCALL button

Press to call the operator of the HDCU-900 Camera Control Unit, the MSU-700A/750 Master Setup Unit, or the RCP-700 series Remote Control Panel. When pressed, the camera’s red tally lamp will light up if previously off, and turn off if previously on. The CALL button on the MSU-700A/750 Master Setup Unit or RCP-700 series Remote Control Panel will light up, and their buzzer will sound.

When the CALL button on the RCP-700 series Remote Control Panel or the MSU-700A/750 is pressed, this button will light up.

rCURSOR (cursor memory) 1, 2, and 3 buttons Used to store the size and position of the box cursor displayed on the viewfinder screen. Three different box cursor settings may be stored in memory using buttons 1, 2, and 3. Pressing one of these buttons will cause a cursor of the stored size to be displayed in the stored position.

Note

When one of the CURSOR buttons is lit up, the HPOSI, V-POSI, WIDTH, and HEIGHT buttons will be disabled.

HDC-900/950/930 Series Product Information Manual

Chapter 7 Location and Function of Parts and Controls 80

Page 80
Image 80
Sony 900 ND filter selector, Selected filter, CC color temperature conversion filter selector, VF viewfinder Scan switch