Character display of the CNU-700 (in MSU Assignment mode)

MSU assignment

OFF SUPERVISER MSU mode

ON LOCAL MSU mode

 

 

 

1

- 6

CAMERA SELECT

 

 

NEXT

7

- 12

/ACTIVE assignment

 

 

 

 

 

 

– – – –

– – – –

– – – –

4.Select the control mode.

SUPERVISER MSU mode: To control the cameras connected to the entire CNU (Camera Network Unit) in the same system.

LOCALMSU mode: To control the cameras connected to only the CNU (Camera Network Unit) connected to the MSU-700A/750 being operated.

Selection can be linked between the camera select buttons on the MSU-700A/750 and the HD router (MP-1007) and routing switcher (DVS-V1201). In this case, 9-pin cables are needed to connect between the MP-1007 and DVS-V1201.

Move the cursor to the mode in OFF status and press [Set] on the MSU Assignment menu to switch between modes. When the SUPERVISER mode is active, you can select the setting display for each camera group in the same system from the lower rows on the character display of the CNU-700.

5.Select the camera group to be set.

In LOCAL MSU mode, only the group of cameras 1 through 12 (standard) can be selected. Pressing [Set] on the MSU Assignment menu with the cursor on [NEXT] calls up the setting display for the selected camera group.

Example: Setting display in LOCAL MSU mode

MSU assignment [LOCAL]

 

 

 

Ret

mode cannot be selected anymore. If this occurs, change the MSU assignment as described in "To restore operations of the MSU-700A/750" on the next page.

To resume the initial assignment

Press [Default] on the MSU Assignment menu.

7.When your settings are completed, press [Set] on the MSU Assignment menu with the cursor on [Ret] in the upper right of the CNU character display. (To cancel the settings, press [Cancel].)

The character display of the CNU-700 returns to its previous status (MSU Assignment display).

In SUPERVISER MSU mode, perform the settings for the cameras of other groups in the same manner.

When the MSU assignment is completed Press [Exit] on the MSU Assignment menu.

6-3-3-1To restore operations of the MSU- 700A/750

If the MSU-700A/750 has become inoperative by disabling the selection/control for all the connected cameras, change the MSU assignment using the internal switches of the CNU-700 as follows:

AT

+5

MODE

CHARACTER

 

 

PHASE

 

 

UP DOWN SET

CANCEL

SET/CANCEL switch

UP/DOWN switch

MODE switch

1.

Set the MODE switch to 3.

 

The message "MSU Assignment" appears on the

 

screen.

2.

Push the SET/CANCEL switch (S6) toward SET.

 

The same MSU Assignment display as that in step

 

3 on the previous page appears. Each press of the

 

UP/DOWN switch (S5) toward DOWN moves the

 

cursor on the display to the right, or down when it

 

reaches the right edge of the frame. Each press of

 

the switch toward UP moves the cursor to the left,

 

or up when it reaches the left edge of the frame.

3.

Move the cursor to the desired position, then push

1CAM

2CAM

3CAM

4CAM

5CAM

6CAM

Camera Select

Active/Para

Camera Select

Active/Para

Camera Select

Active/Para

Camera Select

Active/Para

Camera Select

Active/Para

Camera Select

Active/Para

7CAM

8CAM

9CAM

10CAM

11CAM

12CAM

Camera Select

Active/Para

Camera Select

Active/Para

Camera Select

Active/Para

Camera Select

Active/Para

Camera Select

Active/Para

Camera Select

Active/Para

 

the SET/CANCEL switch (S6) toward SET.

4.

Repeatedly push the UP/DOWN switch (S5) toward

 

UP until the cursor reaches the SAVE position

 

outside the frame.

5.

Push the SET/CANCEL switch (S6) towards SET.

 

The assignment set in steps 3 and 4 is written to

 

nonvolatile memory.

6.

Return the MODE switch to 0.

6.Select the control functions for each camera. Camera Select: Selection by the corresponding

camera select button on the MSU-700A/750 Active/Para: Control from the MSU-700A/750 in

Panel Active/Parallel mode.

Each item is on (selection/control enabled) when the characters are shown in black, and off (selection/control disabled) when the characters are shown in white. Each time [Set] is pressed on the MSU Assignment menu with the cursor on the item turns it on or off.

Caution

Be sure to enable the camera selection for at least one camera. If selection/control is disabled for all the connected cameras, the MSU-700A/750 becomes inoperative and the MSU Assignment

6-3-4Setting the Operating Conditions of the MSU