Sony 900, 930, 950 manual 1Connector Panel, Remote CCU/CNU

Models: 950 930 900

1 203
Download 203 pages 14.22 Kb
Page 164
Image 164

8

8-6-2Cable Wiring

CCA-5 Cable

1

2 7

8

3 6

4 5

8-pin connector (Male)

(Wiring side)

 

Black

 

 

White

 

 

Orange

 

 

White

 

 

Brown

 

 

 

1

 

2

7

 

3

8

 

6

Red

4

5

 

White

 

 

Red

 

Brown

Brown

 

8-pin connector (Male)

(Wiring side)

8-6-3Connection Connector

Connections made with the connector panels during

CCA-5 cable assembly

installation or service should be made with the

(Option)

connectors/complete cable assemblies specified in

CCA-5-3 (3 m)/CCA-5-10 (10

the following list, or equivalent parts.

m)

 

I/O PORT (50-pin)

Plug, D-SUB 50-pin, Male

Connector name

Connection connector/cable

(Sony part number: 1-566-

REMOTE AUX (8-pin)

Plug 8-pin, Male (Sony part

358-11)

 

number: 1-766-848-11)

or

REMOTE CCU/CNU

 

JAE DDU-50PF-F0 or

(8-pin)

or

equivalent

8-7.MSU-750, Master Setup Unit

8-7-1Connector Panel

1POWER switch

2AC IN connector

AUX

REMOTE

POWER

-AC IN

CCU/CNU

I

 

 

 

 

 

 

O

 

4CCU/CNU REMOTE connector

3AUX REMOTE connector

aPOWER switch

Turns the power on and off of this unit.

bAC IN (AC power input) connector

Connect to an AC power source using an optional AC power cord. The power cord can be fixed to this unit using an optional plug retainer.

cAUX REMOTE (auxiliary remote) connector (8- pin)

dCCU/CNU REMOTE (camera control unit/camera command network unit remote) connector (8- pin)

Connect to the RCP/CNU connector of the CCU or the MSU connector of the CNU.

HDC-900/950/930 Series Product Information Manual

Chapter 8 Connectors and Cables 164

Page 164
Image 164
Sony 900, 930, 950 manual 1Connector Panel, Remote CCU/CNU