7

7-3-5HKCU-901 SD Analog Interface Unit

 

The optional HKCU-901 is - installed in the HDCU-900

Note

 

expansion slot.

All input and output connectors function when the

 

 

system is operated at a 59.94/50 Hz field frequency,

but do not operate when the system field frequency is 60 Hz.

1RET INPUT 1-4 connectors

2SYNC OUT connector

3 PIX OUT connector

4 WF OUT connector

5 Y/G, B-Y/B, and R-Y/R OUTPUT connectors

6 VBS OUT 1 and 2 connectors

1

2

3

4

Y/G

B-Y/B

R-Y/R

1

2

RET INPUT

SYNC OUT PIX OUT WF OUT

OUTPUT

VBS OUT

aRET INPUT 1-4 (return video 1, 2, 3, and 4 input)

connectors (BNC type)

Four different SD analog return video input signals may be received independently. The selection of RET

1, 2, 3, or 4 is made by the camera’s return switch. The type of input signal on RET 1, 2, 3, and 4 may be set individually using switches on the AT board in the HDCU-900, or using the MSU-700A/750 Master Setup Unit. The aspect ratio may also be selected for SD signals.

Note

If a signal asynchronous with the HDCU-900 is supplied, the picture quality may be degraded.

bSYNC OUT (SD sync signal output) connector (BNC type)

Used for output of an SD composite sync signal from the internal sync signal generator.

cPIX OUT (picture monitor output) connector (BNC type)

Used for output of the picture monitor video signal selected using the RCP-700 series Remote Control Panel MONITOR SELECT button, or the MSU-700A/ 750 Master Setup Unit PICTURE MONITOR button. (When both the RCP and MSU are in use, this connector can be assigned to the output connector for MSU control.) Signal selection can be made using switches on the AT board.

dWF OUT (waveform monitor output) connector (BNC type)

Used for output of the waveform monitor video signal selected using the RCP-700 series Remote Control Panel MONITOR SELECT button, or the MSU-700A/ 750 Master Setup Unit WF MONITOR button.

(When both the RCP and MSU are in use, this connector can be assigned to the output connector for MSU control.) Signal selection can be made using switches on the AT board.

eY/G, B-Y/B, and R-Y/R OUTPUT (component video signal output) connectors (BNC type)

Used for output of either Y, B-Y, R-Y component video or G, B, R component video signals. The type of signal

is selected using switches on the AT board. (Factory setting: G, B, R)

fVBS OUT 1 and 2 (composite video output 1 and

2) connectors (BNC type)

The two connectors are for output of the video camera signal in analog composite video format.

HDC-900/950/930 Series Product Information Manual

Chapter 7 Location and Function of Parts and Controls 91

Page 91
Image 91
Sony 950 But do not operate when the system field frequency is 60 Hz, Sync OUT SD sync signal output connector BNC type