7 7-9.MSU-750, Master Setup Unit

7-9-1Operation Panel

1 ALL button

2 CAM PW button

3 VF PW button

4 Signal output select buttons

5 CLOSE button

6 STANDARD button

7 AUTO SETUP block

8Camera/CCU function ON/OFF buttons

9Scene file control block

q; Monitor output select buttons

AUTO SETUP

 

 

 

 

 

 

AUTO LEVEL START/

 

ALL CAM PW VF PW

TEST BARS

CLOSE STANDARD HUE

BREAK WHITE BLACK

5600K

AUTO

SKIN

 

 

CHARACTER ECS/SHUTTER

GAMMA

MASTER

ND CC

 

KNEE

DETAIL

 

 

 

 

GAIN

FILTER

1

2

3

4

5

 

ACCESS

 

 

 

 

 

 

 

 

 

 

SCENE FILES

 

STORE

 

 

 

R

G

B

SEQ

ENC

 

IC MEMORY CARD

 

 

 

 

 

 

 

 

 

MONITOR

WF

PIX

 

 

 

 

 

 

 

 

 

 

 

qs Display window block

qd IC card insertion block

qa Camera select block

MODE

MULTI

CARD

CONFIG

MAINTENANCE

FILE

PAINT FUNCTION

PANEL

PARA

EXPAND

 

 

 

ACTIVE

 

 

 

 

 

 

 

 

 

 

MULTI

 

 

 

 

 

TALLY

0 7

0 8

0 9

1 0

1 1

1 2

 

 

 

 

 

MULTI

 

 

 

 

 

TALLY

0 1

0 2

0 3

0 4

0 5

0 6

MASTER BLACK

CALL

IRIS/MB

ACTIVE

EXTAUTO

IRIS

MASTER SETUP UNIT

qf Menu operation block

qg CALL button

qh IRIS/MB ACTIVE button

qj Iris control block

ql Camera number/tally indication window qk MASTER BLACK control block

aALL button

Press the button so it starts flashing to activate the 11 buttons located at the right (from CAM PW to AUTO SETUP) for all the connected cameras of the same group.

bCAM PW (camera power) button

Press and light up this button to turn the power supply to the video camera ON. (The button promptly flashes until the camera becomes ready for transmission.)

When you press this button again, it starts flashing and the power supply to the camera is turned off.

cVF PW (viewfinder power) button

Press and light up this button to turn the power supply to the viewfinder ON. When you press the button again, it goes dark and the power supply is turned off.

dSignal output select buttons

Press and light up one of these buttons to activate the test signal generator of the video camera and send the respective signals.

TEST: To send a signal to test the video circuits

BARS: To send a color bar signal

Note

The BARS button takes priority to the TEST button. If the BARS button is lit, press the button to turn it dark before pressing the TEST button.

eCLOSE (iris close) button

Press and light the button to close the iris. Press again to release the close mode.

HDC-900/950/930 Series Product Information Manual

Chapter 7 Location and Function of Parts and Controls 112

Page 112
Image 112
Sony 950, 930, 900 manual MSU-750, Master Setup Unit, Signal output select buttons