7

7-3-4SD Signal Input/Output Block

These connectors can be replaced with the optional

HKCU-902/903/904.

1SERIAL RET INPUT 1-4 connectors

2SYNC OUT connector

3 PIX OUT connector

4 WF OUT connector

5 WF MODE connector

6 SERIAL OUTPUT 1-4 connectors

1

2

3

4

1

2

3

4

SERIAL RET INPUT

SYNC OUT

PIX OUT

WF OUT

WF MODE

SERIAL OUTPUT

aSERIAL RET INPUT 1-4 (SD-SDI return video 1, 2, 3, and 4 input) connectors (BNC type)

Four different SD-SDI return video input signals may be received independently when the system is operating with the field frequency of 59.94/50 Hz. The selection of RET 1, 2, 3, or 4 is made by the camera’s return switch. The type of input signal on RET 1, 2, 3, and 4 may be set individually using switches on the internal AT board, or using the MSU-700A/750 Master Setup Unit. The aspect ratio may also be selected for SD signals.

bSYNC OUT (HD/SD sync signal output) connector (BNC type)

Used for output of an HD tri-level sync or SD composite sync signal from the internal sync signal generator. (Factory setting: HD tri-level sync)

cPIX OUT (picture monitor output) connector (BNC type)

Used for output of the picture monitor video signal selected using the RCP-700 series Remote Control Panel MONITOR SELECT button, or the MSU-700A/ 750 Master Setup Unit PICTURE MONITOR button. (When both the RCP and MSU are in use, this connector functions as the output connector for RCP control.)

dWF OUT (waveform monitor output) connector (BNC type)

Used for output of the waveform monitor video signal selected using the RCP-700-series Remote Control Panel MONITOR SELECT button, or the MSU-700A/ 750 Master Setup Unit WF MONITOR button. (When both the RCP and MSU are in use, this connector functions as the output connector for RCP control.)

Note

The SC phase of the VBS signal output from connectors 3 and 4 is not locked to the black burst signal supplied to the REFERENCE IN connector. Use the monitor in Internal sync mode.

eWF MODE (waveform monitor mode) connector (4-pin)

Connect to the appropriate connector on a waveform monitor when monitoring a signal in sequential mode. A sequence signal will be output when the SEQ button on the RCP-700 series Remote Control Panel is pressed, allowing simultaneous monitoring of the R, G, and B signals in sequential mode. (When both the RCP and MSU are in use, this connector functions as the output connector for RCP control.)

fSERIAL OUTPUT 1-4 (SD-SDI 1, 2, 3, and 4 output) connectors (BNC type)

When the system is operating with the field frequency of 59.94/50 Hz, the signal from the video camera may be down converted and output as four SD component SDI signals.

HDC-900/950/930 Series Product Information Manual

Chapter 7 Location and Function of Parts and Controls 90

Page 90
Image 90
Sony 930, 950, 900 manual HKCU-902/903/904, Sync OUT HD/SD sync signal output connector BNC type