7

750 Master Setup Unit or RCP-700 series

Remote Control Panel. Either a recall-type

monitor, or the 1730HD/1735HD Waveform

Monitor, may be connected. When using a recall-type monitor, preset a display mode on the waveform monitor, and then recall the mode externally. Switches on the AT board are used to select either recall type or 1730HD/1735HD type operation.

CTRUNK LINE connector (D-sub 9-pin, RS- 232C) Used to connect the HDCU-900 to the TRACKER connector on an HDC-900 HD Color Video Camera via an RS-232C interface. Used mainly for communication with equipment on the camera side. The RXD, TXD, RTS, and CTS signals can be transferred at up to 19.2 kbps

using this connector.

DMIC REMOTE (microphone remote) connector (D-sub 15-pin)

Using this connector, the video camera’s microphone input level may be set by external equipment such as an audio mixer, in five steps (–60, –50, –40, –30, and –20 dB). When taping,

set the volume to a level appropriate for the audio conditions.

EI/O PORT connector (D-sub 15-pin) Used for remote control using an external control device.

Note

Use of a case wider than 42 mm can cause interference at connectors 2, 4, 5. It is recommended to use JAE-made DA-C1-J10.

dCHARACTER OUTPUT connector (BNC type) Used to output the results of the HDCU-900 diagnostic self-test in SD black and white analog video format.

eDIGITAL AUDIO connector (BNC type) Used to output a digital audio signal input to the camera.

fMIC OUTPUT (microphone output) connectors (XLR 3-pin)

Used for output of the microphone input to the video camera.

gINTERCOM/TALLY/PGM (program audio)

connector (D-sub 25-pin)

Used for input and output of intercom, tally, and program audio signals. Connect to the intercom/tally/ program audio connector of the intercom system.

hExpansion slot

For installation of the optional HKCU-901 SD Analog Interface Unit, HKCU-902 HD Analog Interface Unit, HKCU-903 Frame Rate Converter Unit, or HKCU-904 Line Converter Unit.

7-3-3HD Signal Input/Output Block

1SERIAL RET INPUT 1-4 connectors

2REFERENCE IN connectors

3PROMPTER IN connectors

 

 

 

 

 

4 SERIAL OUTPUT 1-3 connectors

 

 

 

 

 

 

 

5 SERIAL OUTPUT MONI

 

 

 

 

 

 

 

connector

1

2

3

4

 

1

2

3

MONI

 

SERIAL RET INPUT

 

REFERENCE IN

PROMPTER IN

 

SERIAL OUTPUT

 

aSERIAL RET INPUT 1-4 (HD-SDI return video 1, 2, 3, and 4 input) connectors (BNC type)

Four different HD-SDI return video input signals may be received independently. The selection of RET 1, 2, 3, or 4 is made by the camera’s return switch. The type of input signal on RET 1, 2, 3, and 4 may be set individually using switches on the internal AT board, or using the MSU-700A/750 Master Setup Unit.

bREFERENCE IN connectors (BNC type)

Used to input an HD tri-level reference sync signal or SD reference sync signal (black burst signal). If loop- through output is not used, terminate the unused connector with 75 ohms.

Note

To use the VBS signal of the HKCU-901 (when SC phase lock is required), use an SD reference sync signal (black burst signal).

cPROMPTER IN connectors (BNC type)

Used for prompter signal input. If loop-through output is not used, terminate the unused connector with 75 ohms. If the signal used is a 1.0 Vp-p, 75-ohm signal, it may be output from the video camera PROMPTER OUT connector with a frequency bandwidth of 8 MHz, regardless of signal format.

dSERIAL OUTPUT 1-3 (HD-SDI 1, 2, and 3 output) connectors (BNC type)

The signal from the video camera may be output as three HD-SDI signals.

eSERIAL OUTPUT MONI (HD-SDI monitor output) connector (BNC type)

The signal from the video camera may be mixed with skin tone gate signals and some aspect marker signal and output in HD-SDI format.

HDC-900/950/930 Series Product Information Manual

Chapter 7 Location and Function of Parts and Controls 89

Page 89
Image 89
Sony 900, 930, 950 manual 3HD Signal Input/Output Block