7

7-3-6HKCU-902 HD Analog Interface Unit

The optional HKCU-902 is designed to be installed in

 

the HDCU-900 expansion slot or in place of the SD

 

signal input/output block.

1 RET INPUT 1-4 connectors

2 SYNC OUT connector

3 PIX OUT connector

4 OUTPUT 1, 2 connectors

1

2

3

4

Y/G

PB/B

PR/R

Y/G

PB/B

PR/R

RET INPUT

SYNC OUT

PIX OUT

OUTPUT 1

OUTPUT 2

aRET INPUT 1-4 (return video 1, 2, 3, and 4 input)

connectors (BNC type)

Four different HD analog return video input signals may be received independently. The selection of RET 1, 2, 3, or 4 is made by the camera’s return switch. The type of input signal on RET 1, 2, 3, and 4 may be set individually using switches on the AT board in the HDCU-900, or using the MSU-700A/750 Master Setup Unit.

bSYNC OUT (HD sync signal output) connector (BNC type)

Used for output of an HD tri-level sync signal from the internal sync signal generator.

cPIX OUT (HD picture monitor output) connector

(BNC type)

Used for output of the picture monitor video signal selected using the RCP-700 series Remote Control Panel MONITOR SELECT button, or the MSU-700A/ 750 Master Setup Unit PICTURE MONITOR button.

Either the Remote Control Panel or Master Setup Unit may control the output, depending on which button was pressed most recently.

dOUTPUT 1, 2 (HD analog component video 1 and 2 output) connectors (BNC type)

HD analog component video signals are output in either Y, PB, PR or G, B, R format. The selection of Y, PB, PR or G, B, R format may be made independently for OUTPUT 1 and OUTPUT 2, using switches on the AT board. (Factory setting: G, B, R)

7-3-7HKCU-903 Frame Rate Converter Unit

The optional HKCU-903 is to be installed in the HDCU- 900 expansion slot or in place of the SD signal input/ output block.

1SERIAL RET INPUT 1-4 connectors

2SYNC OUT connectors

3FRAME REFERENCE IN/OUT connectors

4 SERIAL OUTPUT 1 to 3 and MONI connectors

1

2

3

4

IN

OUT

1

2

3

MONI

SERIAL RET INPUT

SYNC OUT

SYNC OUT

FRAME REFERENCE

SERIAL OUTPUT

aSERIAL RET INPUT 1-4 (HD-SDI return video 1,

2, 3, and 4 input) connectors (BNC type)

Four different HD-SDI return video input signals may be received independently. The selection of RET 1, 2, 3, or 4 is made by the camera’s return switch. The type of input signal on RET 1, 2, 3, and 4 may be set individually using switches on the AT board in the HDCU-900, or using the MSU-700A/750 Master Setup Unit.

bSYNC OUT (HD/SD sync signal output) connectors (BNC type)

The left connector outputs a sync signal of the same format as that of the input/output block in the above slot. The right connector outputs the HD tri-level sync signal of the same format as that of the SERIAL OUTPUT 1 to 3 connectors.

HDC-900/950/930 Series Product Information Manual

Chapter 7 Location and Function of Parts and Controls 92

Page 92
Image 92
Sony 900, 930, 950 manual 7HKCU-903 Frame Rate Converter Unit, Sync OUT HD sync signal output connector BNC type