User’s Manual

-Dial-out Idle Time

This item indicates the longest amount of time that the modem connection remains active if there is no acknowledgement from the remote pc. The value can be set from 1 min to 600 min. If selecting <0>, the modem connection keeps active continuously.

-Dial-out Max Time

This item indicates the longest amount of time that the connection via modem remains active. The value can be set from 1 min to 600 min, or <0> to keep the connection indefinitely.

-Connect

When the Dial-out related settings are configured, set this item to <YES> to starting dial-out or select <NO> to disconnect.

5.1.6.5Trigger Port

To avoid the possibility of the default service port (port 100)being blocked, this item enables the user to change port 100 into another port.

To change the trigger port, move the cursor over <Trigger Port> and press ENTER, then adjust the setting by UP / DOWN keys.

5.1.6.6Email Address

This item is used to edit the e-mail address where alarm event information will be sent. Follow these steps to setup the e-mail address.

Select <Email Address> from Network Setup menu and press ENTER. A virtual keyboard displays.

Use Direction keys to move the cursor for selecting character.

Press ENTER to add the selected character to the password entry field.

When done, move the cursor to <OK> and press ENTER to save the settings and exit.

DVR-4TN/8TN/16TN/ 16TS/16TT Series

69

SPECO TECHNOLOGIES 01/06

 

Page 70
Image 70
Speco Technologies DVR-4TN, DVR-8TN, DVR-16TS Dial-out Idle Time, Dial-out Max Time, Connect, Trigger Port, Email Address