User’s Manual
5.6.3Email Notice
The item enables (ON) / disables (OFF) the Email notification of an event. When an alarm event is triggered and <Email Notice> is enabled, an
NOTE: In order to send an event notification
5.6.4Event Full Screen
This function allows the unit to display the alarm channel in full screen size when an alarm is triggered.
Select <None> to enable this function; select <Main> to display the alarm channel on Main Monitor when an alarm is triggered; select <Call> to display the alarm channel on Call Monitor; and select <Both> to display the alarm channel on both Main Monitor and Call Monitor.
5.6.5Event Duration
This item determines the duration of the buzzer and Alarm Out relay function after an alarm is triggered. The available event duration range is from 5 second to 999 seconds. The default setting is 5 seconds.
5.6.6Per Channel Config
This menu is used to set the Video Loss Detect, Motion Detect and Alarm In / Out function for each channel. The menu is displayed as below.
|
| Per Channel Config |
1. | Channel Select | CH1 |
2. | Video Loss Detect | OFF |
3. | Motion Detect | OFF |
4. | Detection Config | OFF |
5. Alarm In | ||
6. Alarm Out | None |
91 | |