5.4.4.4Event Max PPS

Event Max PPS is used to set the event recording rate for Event status. Normally, the Event PPS is set to be equal to or greater than Normal PPS; the setting depends on your application. If the Event PPS is set to <0>, the DVR-4TN/8TN/16TN/16TS/16TTseries unit stops recording event video during alarms.

5.4.4.5Event Qlty

This item is used to set the picture size for event status recording. Refer to Section 5.4.4.3 for the available options.

5.4.4.6Event Active

Users are allowed to choose which alarm type needs to be recorded. The available options are <Alarm> (alarm events), <Motion> (motion detection events), <Both> (alarm event + motion detection), and <None> (no events active). The default setting is <Both>, which includes Alarm and Motion event recording.

5.4.5ezRecord Setup

This item aims to avoid the complicated record settings and to make the setup much easier. Note that this item can be reached only when you select <ezRecord> as the option for <Preset Config>. For more information, please refer to the Appendix J: ezRecord Diagram Sample.

Select <ezRecord Setup> from <Record Setup> and press ENTER, the sub-menu appears as shown below:

ezRecord Setup

 

How Many Days To Record

1 Days

Daytime Record

Yes

Night Record

Yes

Weekend Record

Yes

Overall Recording Condition

Best

DVR-4TN/8TN/16TN/ 16TS/16TT Series