SPTRUNC Convert Single-Precision Floating-Point Value to Integer With Truncation

 

 

Convert Single-Precision Floating-Point Value to Integer With Truncation

SPTRUNC

 

Syntax

 

 

 

 

SPTRUNC (.unit) src2, dst

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.unit = .L1 or .L2

 

 

 

 

 

 

 

 

 

 

 

Compatibility

 

 

C67x and C67x+ CPU

 

 

 

 

 

 

 

 

 

 

Opcode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31

29

28

27

23

22

18

17

13

12

11

5

4

3

2

1

0

creg

z

dst

src2

0 0 0 0 0 x 0 0 0 1 0 1 1

1 1 0 s p

3 15511 1

Opcode map field used...

For operand type...

Unit

 

 

 

src2

xsp

.L1, .L2

dst

sint

 

 

 

 

Description

The single-precision value in src2 is converted to an integer and placed in dst.

 

This instruction operates like SPINT except that the rounding modes in the

 

FADCR are ignored, and round toward zero (truncate) is always used.

Execution

if (cond)

int(src2) dst

 

else

nop

Notes:

1)If src2 is NaN, the maximum signed integer (7FFF FFFFh or 8000 0000h) is placed in dst and the INVAL bit is set.

2)If src2 is signed infinity or if overflow occurs, the maximum signed integer

(7FFF FFFFh or 8000 0000h) is placed in dst and the INEX and OVER bits are set. Overflow occurs if src2 is greater than 231 − 1 or less than −231.

3)If src2 is denormalized, 0000 0000h is placed in dst and INEX and DEN2 bits are set.

4)If rounding is performed, the INEX bit is set.