NOP No Operation

 

No Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Syntax

 

NOP [count]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.unit = none

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compatibility

 

C62x, C64x, C67x, and C67x+ CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opcode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31

18

17

16

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Reserved

0

src

0

0

0

0 0 0 0 0 0 0 0 0 p

1441

Opcode map field used...

For operand type...

Unit

 

 

 

src

ucst4

none

 

 

 

Description

src is encoded as count − 1. For src + 1 cycles, no operation is performed. The

 

maximum value for count is 9. NOP with no operand is treated like NOP 1 with

 

src encoded as 0000.

 

A multicycle NOP will not finish if a branch is completed first. For example, if

 

a branch is initiated on cycle n and a NOP 5 instruction is initiated on cycle

 

n + 3, the branch is complete on cycle n + 6 and the NOP is executed only from

 

cycle n + 3 to cycle n + 5. A single-cycle NOP in parallel with other instructions

 

does not affect operation.

Execution

No operation for count cycles

Instruction Type

NOP

Delay Slots

0

3-190

Instruction Set

SPRU733

Page 250
Image 250
Texas Instruments TMS320C67X/C67X+ DSP manual No Operation, Nop, Ucst4 None