E6581090
11.3Extended parameters
•Input/output parameters
| Communication |
|
| Minimum setting |
| Default | User |
|
|
|
Title | Function | Unit | unit Panel/ | Adjustment range | Reference |
|
| |||
No. | setting | setting |
| |||||||
|
|
|
| Communication |
|
|
|
|
|
|
H | 0100 | Low speed signal | Hz | 0.1/0.01 | 0.6 |
| 6.1.1 |
|
| |
|
| output frequency |
|
|
|
|
|
|
|
|
H | 0101 | Hz | 0.1/0.01 | 0.0 |
| 6.1.2 |
|
| ||
|
| frequency |
|
|
|
|
|
|
|
|
H | 0109 | Analog input/logic | - | - | 0:Voltage signal input | 0 |
| 6.2.1 |
|
|
|
| input function |
|
|
|
|
|
|
| |
|
| selection (VI/S3) |
|
| 1:Current signal input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 2:Contact input |
|
|
|
|
|
H | 0110 | Always active | - | - | 0~40, 49, 54~57 | 1 |
| 6.2.2 |
|
|
|
| function selection |
|
|
| (ST) |
|
|
|
|
H | 0111 | Input terminal | - | - | 0~40, 49, 54~57 | 2 |
| 6.2.3 |
|
|
|
| selection 1 (F) |
|
|
| (F) |
|
|
|
|
H | 0112 | Input terminal | - | - | 0~40, 49, 54~57 | 3 |
| 6.2.3 |
|
|
|
| selection 2 (R) |
|
|
| (R) |
|
|
|
|
H | 0113 | Input terminal | - | - | 0~40, 49, 54~57 | 6 |
| 6.2.3 |
|
|
|
| selection 3 (S1) |
|
|
| (SS1) |
|
|
|
|
H | 0114 | Input terminal | - | - | 0~40, 49, 54~57 | 7 |
| 6.2.3 |
|
|
|
| selection 4 (S2) |
|
|
| (SS2) |
|
|
|
|
H | 0115 | Input terminal | - | - | 8 |
| 6.2.3 |
|
| |
|
| selection 5 (VI/S3)*5 |
|
|
| (SS3) |
|
|
|
|
H | 0127 | Sink/Source selection | - | - | 0: Sink 100: Source | *2 |
| 6.2.5 |
|
|
|
|
|
|
|
|
|
|
|
| |
H | 0130 | Output terminal | - | - | 4 |
| 6.2.6 |
|
| |
|
| selection 1 |
|
|
| (LOW) |
|
|
|
|
|
|
|
|
|
|
|
| 11 | ||
|
| (FM/OUT)*6 |
|
|
|
|
|
|
| |
H | 0132 | Output terminal | - | - | 10 |
| 6.2.6 |
|
| |
|
| selection 3 (FL) |
|
|
| (FL) |
|
|
|
|
H | 0170 | Base frequency 2 | Hz | 0.1/0.01 | *2 |
| 6.3.1 |
|
| |
H | 0171 | Base frequency | V | 1/1 | *2 |
| 6.3.1 |
|
| |
|
| voltage 2 |
|
|
|
|
|
|
|
|
H | 0172 | Torque boost 2 | % | 0.1/0.1 | *3 |
| 6.3.1 |
|
| |
H | 0173 | Motor thermal | % | 1/1 | 100 |
| 6.3.1 |
|
| |
|
| protection level 2 |
|
|
|
|
|
|
|
|
*2: The value is changed according to the
FH:80, UL80, VL:60, F127:0, F170:60, F171:200, F204:80, F409:200, F417:1710 for VFNC1
□P□ type.
*3: Parameter values vary depending on the capacity. Refer to page
*5: This function is enabled if F109 is set at 2 (logic input).
*6: This function is enabled if FMSL (open collector output) is set at 1.