supplyPower Rating
Item
Input voltage
Applicable motor (kW)
Type
Form
Capacity (kVA) Note 1)
Rated output current (A)
Note 2)
Rated output voltage
Note 3)
Overload current rating
Allowable fluctuation
Ampere Interrupt
Capacity (A) AIC
Protective method
Cooling method
Color
Charge lamp
|
|
|
|
|
| E6581090 |
|
| Specification |
|
| ||
|
|
|
| |||
0.1 | 0.2 | 0.4 |
| 0.75 | 1.5 | 2.2 |
|
|
| VFNC1S |
|
| |
1001P | 1002P | 1004P |
| 1007P | - | - |
0.3 | 0.6 | 1.0 |
| 1.6 | - | - |
0.7 | 1.4 | 2.4 |
| 4.0 | - | - |
|
|
|
|
|
|
|
60seconds at 150%,
Voltage +10%,
1000 | 1000 | 1000 |
| 1000 | - | - |
|
| IP20 Enclosed type (JEM 1030) |
|
| ||
|
|
|
| Forced | - | - |
|
|
| ||||
|
| Munsel | 5Y8/0.5 |
|
| |
| LED indicating the charge status of the capacitor in the main circuit |
| ||||
|
|
| - |
|
|
|
|
| Item |
|
|
| Specification |
|
| |||
|
|
| Input voltage |
|
|
|
| |||||
|
|
| Applicable motor (kW) | 0.1 | 0.2 |
| 0.4 |
| 0.75 |
| 1.5 | 2.2 |
|
|
| Type |
|
|
| VFNC1S |
|
|
|
| |
|
|
| Form | - | 2002PL |
| 2004PL |
| 2007PL |
| 2015PL | 2022PL |
|
| Rating | Capacity (kVA) Note 1) | - | 0.5 |
| 0.9 |
| 1.6 |
| 2.9 | 4.1 |
|
| Note 2) |
|
|
|
|
|
|
|
|
| |
|
|
| Rated output current (A) | - | 1.2 |
| 2.3 |
| 4.0 |
| 7.5 | 10.7 |
|
|
|
|
|
|
| ||||||
|
|
| Rated output voltage |
|
|
|
|
| ||||
|
|
| Note 3) |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Overload current rating |
|
| 60 seconds at 150%, |
|
| ||||
|
| Power supply |
|
|
|
|
| |||||
|
| Allowable fluctuation |
| Voltage +10%, |
| |||||||
|
| Ampere Interrupt | - | 1000 |
| 1000 |
| 1000 |
| 5000 | 5000 | |
|
|
| Capacity (A) AIC |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| |
12 |
|
| Protective method |
|
|
| IP20 Enclosed | type (JEM 1030) |
|
|
| |
|
| Cooling method | - |
|
|
|
| Forced | ||||
|
|
|
|
|
|
| ||||||
|
|
| Color |
|
|
| Munsel 5Y8/0.5 |
|
|
| ||
|
|
| Charge lamp |
|
|
| None |
|
|
|
| |
|
|
|
|
|
| EMC noise filter (Class B) |
|
|
Note)
1.Capacity is calculated at 220V for the 200V models.
2.Indicates rated output current setting when the PWM carrier frequency (parameter H) is 4kHz or less.
If the PWM carrier frequency setting is fixed above 4 kHz, the rated current needs to be reduced. If the PWM carrier frequency is set above 4 kHz, it could fall automatically if an
The default setting of the PWN carrier frequency is 12kHz.
3.Maximum output voltage is the same as the input voltage.
With regard to 100V models, the output voltage may decrease about 10 to 20 % if motor load is applied. When operating VFNC1 in conjunction with general purpose motor (200V), it is necessary to reduce the motor load.
4.±10% when the inverter is used continuously (load of 100%).