E6581090

6.6DC braking

6.6.1DC braking

H

H

H

:DC braking starting frequency (Hz)

:DC braking current (%)

:DC braking time (s)

Function

Large braking torque can be obtained by applying a direct current to the motor. These parameters are used to set the direct current to be applied to the motor, the application time and the starting frequency.

[Parameter setting]

 

 

 

 

6

 

Title

Function

Adjustment range

Default setting

 

 

 

 

 

 

 

 

 

H

DC braking starting frequency

0.0:(OFF),

0.0

 

 

 

(Hz)

0.1HJ(Hz)

 

 

 

 

 

 

 

 

H

DC braking current (%)

0100(%)

50.0

 

 

 

H

DC braking time (s)

0.0:(OFF)

1.0

 

 

 

0.120.0(sec)

 

 

 

 

 

 

 

 

 

Output frequency [Hz]

 

 

 

 

Set frequency

DC braking stop

DC braking starting frequency H

0

Time [sec]

 

Output current [A]

 

 

 

 

 

 

DC braking current

H

0

 

 

 

 

DC braking time

H

 

Operation signal [F-CC]

ON

OFF

Note: During DC braking, the overload protection sensitivity of the motor increases. To prevent tripping, the DC braking current is adjusted automatically in some cases.

F-11