6.6DC braking
6.6.1DC braking
H
H
H
:DC braking starting frequency (Hz)
:DC braking current (%)
:DC braking time (s)
• Function
Large braking torque can be obtained by applying a direct current to the motor. These parameters are used to set the direct current to be applied to the motor, the application time and the starting frequency.
[Parameter setting] |
|
|
|
| 6 | |
| Title | Function | Adjustment range | Default setting |
| |
|
|
|
|
|
|
|
| H | DC braking starting frequency | 0.0:(OFF), | 0.0 |
|
|
| (Hz) | 0.1~HJ(Hz) |
|
| ||
|
|
|
|
| ||
| H | DC braking current (%) | 0~100(%) | 50.0 |
|
|
| H | DC braking time (s) | 0.0:(OFF) | 1.0 |
|
|
| 0.1~20.0(sec) |
|
| |||
|
|
|
|
|
| |
| Output frequency [Hz] |
|
|
|
|
Set frequency
DC braking stop
DC braking starting frequency H
0 | Time [sec] |
| |
Output current [A] |
| ||
|
|
| |
|
| DC braking current | H |
0 |
|
|
|
| DC braking time | H |
|
Operation signal
ON
OFF