E6581090
13.3If the motor does not run while no trip message is displayed ...
If the motor does not run while no trip message is displayed, follow these steps to track down the cause.
The motor does not run.
Is the
Is QHH displayed?
YES :
NO :
Check the power supply and the MCCB. |
| Supply the |
Is power being supplied normally? |
| power normally. |
|
|
|
Make a service call.
•The
Is any failure message |
| Track down and eliminate the cause of the failure and then reset the | ||
displayed? (See 13.1.) |
| inverter. See 13.2. | ||
|
|
|
|
|
Are TVT[ and a failure message displayed alternately?
Is the RUN lamp blinking?
The inverter is in the process of retrying. The retry function can be disabled by normal or emergency stop operation, or by turning off the inverter.
The inverter is receiving an operation signal. Check whether it has received an operation command. (Check to see that the frequency setting signal level is not zero.)
Is : . displayed?
• Check to see that the frequency setting signal is not set at zero.
•Check the settings of the frequency setting signal parameters HOQF. (See 5.1.)
•Check the frequency setting signal points 1 and 2 settings. (See 6.4.)
•Check that the
•Check that the frequency setting
•Check that the motor is not under a too large load or not locked up. → Reduce the load if necessary.
13
Determine the cause, using the parameter display function and the status monitoring function.
Refer to Section 11 for the parameter display function or Section 8 for the status motoring function.