6.12Improving torque and speed characteristics
6.12.1Setting motor constants
RV
XN
H
H
:V/F control mode selection
:Base frequency 1 (Hz)
:Slip frequency gain
:Base frequency voltage 1 (V) (rated voltage of motor)
★When setting the RV parameter (V/F control mode selection) to 3 (slip correction), adjust the following parameters, too.
Title | Function | Adjustment range | Default setting |
|
| |
XN | Base frequency 1 (Hz) | 25~200 (Hz) | 60 |
|
| |
H | Slip frequency gain | 0~150 (%) | 50 |
|
| |
H | Base frequency voltage 1 (V) | 50~500 (V) | * |
|
| |
6 | ||||||
| (rated voltage of motor) |
|
|
| ||
* The value is changed according to the |
200 [V] for VFNC1
H : Used to set a motor slippage correction factor. There is no need to change the factory default setting under normal conditions. However, if the motor speed fluctuates considerably with load fluctuations, increase the gain to reduce fluctuations of the motor speed.
H : Used to set the rated voltage of the motor. There is no need to change the factory default setting when using ordinary motors. However, when using a motor with a rated voltage and a base frequency other than
6.12.2Optimizing control characteristics
Although there is no need to change the settings of the following parameters under normal conditions, control characteristics may be improved by adjusting the parameters according to the motor specifications and load characteristics.
H : Motor rated current
H : Motor
H : Motor rated speed
H : Speed control gain
H : Speed control stable coefficient
Title | Function | Adjustment range | Default setting | |
H | Motor rated current | Depends on the model | ||
(See Section 11.) | ||||
|
|
| ||
H | Motor | Depends on the model | ||
(See Section 11.) | ||||
|
|
| ||
H | Motor rated speed | * | ||
H | Speed control gain | 0~100(%) | 40 | |
H | Speed control stable coefficient | 0~100(%) | 20 |
*The value is changed according to the
★Enabled if the RV parameter (V/F control mode selection) is set to 0 (V/F) H : Used to adjust the effective response to the frequency command.
•Increase the value to increase response.
•Decrease the value to decrease response.
Adjust the value in increments of 10 (%) or so while checking the effective response.
H : Used to adjust the effective response to the frequency command.
•Increase the value if overshooting or hunting occurs.
•Increase the value if the speed reducer makes a gear noise.
•Increase the value if overvoltage tripping occurs on completion of deceleration. Adjust the value in increments of 10 (%) or so while checking the effective response.