E6581090

Reduction in rated load current

When the PWM carrier frequency is set above 4kHz, the rated current needs to be decreased.

VFNC1S- Ambient VFNC1- temperature

 

2001P

50°C or less

 

2002P

50°C or less

 

2004P

40°C or less

 

40 to 50°C

 

 

 

2007P

40°C or less

 

40 to 50°C

 

 

 

2015P

40°C or less

 

40 to 50°C

 

 

 

2022P

40°C or less

 

40 to 50°C

 

 

 

1001P

50°C or less

 

1002P

50°C or less

 

1004P

40°C or less

 

40 to 50°C

 

 

 

1007P

50°C or less

 

2002PL

40°C or less

 

40 to 50°C

 

 

 

2004PL

40°C or less

 

40 to 50°C

 

 

 

2007PL

40°C or less

 

40 to 50°C

 

 

 

2015PL

40°C or less

 

40 to 50°C

 

 

 

2022PL

40°C or less

 

40 to 50°C

 

 

 

Carrier frequency

 

 

 

4kHz or less

8kHz

12kHz

16kHz

 

 

0.7A

0.7A

0.7A

0.7A

 

 

1.4A

1.4A

1.4A

1.4A

 

 

2.4A

2.4A

2.4A

2.4A

 

 

2.4A

2.4A

2.4A

2.2A

 

 

4A

4A

3.6A

3A

 

 

4A

3.6A

3.2A

2.8A

 

 

7.5A

7.5A

7.5A

7.1A

 

 

7.5A

7.5A

7.1A

6.3A

 

 

10.0A

9.5A

8.5A

7.5A

 

 

10.0A

8.5A

7.5A

6.5A

 

 

0.7A

0.7A

0.7A

0.7A

 

 

1.4A

1.4A

1.4A

1.4A

 

 

2.4A

2.4A

2.4A

2.4A

 

 

6

2.4A

2.4A

2.4A

2.2A

 

4A

4A

4A

4A

 

 

1.2A

1.2A

1.2A

1.2A

 

 

1.1A

1.1A

1.1A

1.1A

 

 

2.3A

2.3A

2.3A

2.3A

 

 

2.1A

2.1A

2.1A

2.1A

 

 

4A

3.6A

3.2A

2.8A

 

 

3.6A

3.2A

2.9A

2.5A

 

 

7.5A

7.5A

7.5A

7.1A

 

 

6.8A

6.8A

6.8A

6.4A

 

 

10.7A

10.1A

9.1A

8A

 

 

9.6A

9.1A

8.2A

7.2A

 

 

Function

Although the rated current at 4kHz is shown on the rating plate, the PWM carrier frequency is set to 12kHz by default.

Note: In order to protect the inverter, PWM carrier frequency may fall automatically depending on the circumstances even if it is under the derating in accordance with above table.

If using foot-mounted type noise reduction filter EMFAS2011Z or EMFA2006Z with VF-nC1, it is necessary to decrease 5% more of rated current in above table.

6.10Trip-less intensification

6.10.1Auto-restart (restart during coasting)

H

: Auto-restart control selection

Caution

Stand clear of motors and mechanical equipment.

If the motor stops because of a momentary power failure, the equipment will start suddenly when the power is restored, and could cause injury.

Mandatory To prevent accidents, attach labels warning that there is the risk of a sudden start in the event of a power failure to all inverters, motors and machines.

Function

This parameter detects the rotational speed and direction of rotation of the motor during coasting in the event of a momentary power failure, and restarts the motor smoothly as soon as power is restored (motor speed search function). Also, this parameter makes it possible to switch from commercial power operation to inverter operation without stopping the motor.

During restart operation, the message “TVT[” is displayed.

F-13