E6581090
Note: The
| • Do not unscrew the power terminals to UP position frequently. (Less than 5 times is |
| |
| recommended) |
| |
| • Do not press the screw when unscrew the main terminals. |
| |
| 1 | ||
| • Do not unscrew quickly like using an Electric screw driver. | ||
| • Do not pull the power wire during unscrewing the power terminals to UP position. | ||
| • Do not unscrew the power terminal to UP position with over torque. |
| |
| • Do not make any deformation of the cover when unscrewing the power terminals. |
| |
1.3.2 | Main circuit and control circuit terminal blocks |
|
|
1) Main circuit terminal block
When using a crimp terminal, cover its caulked part with a tube or use an insulated terminal.
Screw size | tightening torque | ||
M3 screw | 0.8N | ・ | m |
M3.5 screw | 1.0N | ・ | m |
VFNC1-2001P~2007P
[Main circuit input terminals]
[Main circuit output terminals]