3.1.1How to start and stop
(1) Start and stop using the operation panel keys (EOQF : )
Use the RUN and STOP keys on the operation panel to start and stop the motor.
RUN : Motor starts. |
| |
| : Motor stops (slowdown stop). |
|
STOP | 3 | |
|
|
|
(2)Start and stop using external signals to the terminal board (EOQF : )
Use external signals to the inverter terminal board to start and stop the motor. (Sink logic connection)
Short F and CC terminals: run forward | ★Coast stop |
|
| |||||
|
| The standard default setting is for slowdown | ||||||
|
| stop. To make a coast stop, assign an ST | ||||||
Open F and CC terminals: slow down and stop | terminal function to an idle terminal using the | |||||||
programmable terminal function. |
|
| ||||||
|
| For coast stop, open the | ||||||
|
| the motor in the state described at left. The | ||||||
|
| monitor on the inverter at this time will display | ||||||
Frequency | Slowdown stop | QHH. |
|
| ||||
|
|
|
|
|
|
|
| |
| ON | Motor | Coast stop | |||||
speed | ||||||||
OFF |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ON | |
|
|
|
|
|
|
| OFF | |
|
|
|
|
|
|
| ON | |
|
|
|
|
|
| OFF |
3.1.2How to set the frequency
(1)Setting the frequency using the potentiometer on the inverter main unit
(HOQF : )
Set the frequency with the notches on the potentiometer.
Move clockwise through the higher notches for the higher frequencies.
Since the potentiometer has hysteresis, it settings may change to some
degree after the power is turned off and turned back on.