■Example of parameter setting
The steps in setting are as follows. (Example of changing the starting frequency selection H from to .)
Key operated | LED display | Operation | ||
|
|
| Displays the operation frequency (operation stopped). | |
|
| (When standard monitor display selection H= is set to | ||
|
|
| [operation frequency]) | |
| MON | CWJ | The first basic parameter "History (CWJ)" is displayed. | |
|
|
|
| |
▲ | ▼ | H | Press either the △ key or the ▽ key to change to the | |
parameter group H . | ||||
|
|
| ||
| ENT | H | Press the ENTER key to display the first extended parameter | |
| H. | |||
|
|
| ||
▲ | ▼ | H | Press the △ key to change to the dynamic braking selection | |
H. | ||||
|
|
| ||
| ENT | Pressing the ENTER key allows the reading of parameter | ||
| setting. | |||
|
|
|
▲Press the △ key to change the dynamic braking selection
▼ from 0.5Hz to 1.0Hz
ENT | Pressing the ENTER key alternately flashes on and off the | |
⇔ H parameter and changed value and allows the save of those | ||
| ||
| values. |
If there is anything you do not understand during this operation, press the MON key several times to start over from the step of CWJ display.
4.1.4How to set (use) special parameters
(1) Setting a parameter, using the wizard function (CWH)
Wizard function (CWH):
The wizard function refers to the special function of calling up only functions necessary to set up the inverter in response to the user’s needs. When a
Title | Function | Adjustment range | Default setting | |
CWH | Wizard function | 0 : - | 0 | |
|
| 1 | : Basic setting wizard |
|
|
| 2 | : Preset speed operation wizard |
|
|
| 3 | : Analog signal operation wizard |
|
|
| 4 | : Motor 1/2 switching operation wizard |
|
|
| 5 | : Torque up wizard* |
|
* This parameter is valid only for VFNC1