Routine maintenance

CAUTION: Fuser lubricant for other printers is not compatible. Do not use DocuTech and DocuPrint fuser agent in a DocuTech HLC system. Do not use DocuTech HLC fuser shield in a DocuTech 61xx or DocuPrint 1xx system. The fuser lubricants are not compatible and will contaminate the system.

1.Open the processor doors.

2.Place a drop cloth on the floor under the fuser area.

3.Open the fuser drawer.

a.Locate the fuser drawer.

b.Grasp the green handle on the fuser drawer and pull it out until it stops.

Figure 3-21 Opening the fuser drawer

WARNING: Fuser lubricant contains silicone, which can cause irritation upon contact with the eye. Make sure that you wash your hands with soap and water after you finish this procedure.

CAUTION: Fuser lubricant can cause damage to the CCU if any of the it is spilled into the unit. Use extra care to ensure that no fuser lubricant is dripped into the CCU.

4.Wipe the fuser lubricant filler area to remove any residual lubricant.

5.Fill the fuser lubricant reservoir.

a.Pull the fuser lubricant reservoir out until it stops.

b.Remove the reservoir cap by turning it counterclockwise.

3-2 4

DocuTech 128/155/180 HighLight Color Operator Guide

Page 70
Image 70
Xerox 128 manual Opening the fuser drawer