Routinemaintenance

6. Then, turn the yellow CCU handle a quarter turn clockwise.

Figure 3-20 Removing the CCU from the printer

11.Using the metal flange of the color CCU, pull the CCU out of the printer until it is completely in the stand. The flange is located directly below the bottle.

12.To replace the CCU, reverse the above steps.

Adding fuser shield

When directed by a message, add fuser lubricant as soon as possible. If it is not added, the printer stops after approximately 5,000 prints and not run until fuser shield is added. Please read the important note below.

NOTE: In 2006, the formula for the DocuTech HLC fuser lubricant was changed to provide better image quality and to prevent image transfer. The new fuser formula is called Fuser Shield. The fuser blend and the fuser shield CANNOT be intermixed in a DocuTech HLC. To change from one fuser lubricant to another requires a service call and cleaning or replacing components. The two fuser formulas are identified with different color bottles and caps. Be sure the color of the cap of the bottle you are filing from matches the color of the cap already in the system. Fuser shield description: blue bottle, white cap with black printing. Fuser blend description: yellow bottle, black cap with white printing.

WARNING: The fuser area can reach temperatures of approximately 425°F (218°C). Exercise care to prevent burns when working in this area.

DocuTech 128/155/180 HighLight Color Operator Guide