Routine maintenance

Clearing or cleaning the finisher sensors

NOTE: Production publisher configuration only

Clearing the finisher sensors should be performed only when directed by a Customer Support Center Representative.

NOTE: The finisher sensors are located under the processor top cover, under the finisher top cover, and behind the finisher and bindexer doors.

Use the following procedure to clear any obstructions from the finisher sensors.

1.Fold a sheet of 8.5 x 11 inch (216 x 279 mm) paper, as shown in figure 3-36.

Figure 3-36 Folding the paper

2.Use the folded sheet of paper to clear any obstructions in the following sensor areas.

Clearing the Q1201 sensor

NOTE: Production publisher configuration only

Clearing the Q1201 sensor should be performed only when directed by a Customer Support Center Representative.

1.Open the processor top cover.

NOTE: The Q1201 sensor is located under the processor top cover on the right side.

2.Locate the Q1201 sensor, as shown in figure 3-37

3-4 0

DocuTech 128/155/180 HighLight Color Operator Guide

Page 86
Image 86