Table 1-3 describes Centronics interface voltage and current requirements

Table 1-3.

Centronics

interface

voltage

and

current

 

requirements

 

 

 

 

 

 

 

Voltage levels

0 (zero) and +5 VDC (nominal), TTl (SN

 

 

74LS00 series

 

 

 

Logic levels

Positive logic is assumed. A logic one

 

 

(high) signal is defined as a voltage in the

 

 

range of +2.4V to +5V, not to exceed a

 

 

peak of +5.5V.

 

 

 

 

A logic zero (low) signal is defined as a

 

 

voltage in the range of 0.0V to 0.4V, not to

 

exceed a peak negative voltage of -0.5V.

 

 

However for received signals a voltage of up

 

to +0.8V is recognised as a logic zero.

 

Current

The printer interface sources up to -15 ma at

requirements

+2.4V for a high output signal and sinks up

 

to 14 ma for a low output.

 

 

 

74LS374 ICs are used for data receivers with

 

1K ohm pull-up resistors, and 74LS244 ICs

 

are used as drivers for Acknowledge, Busy,

 

Select, etc.

 

 

 

Data rates

The 4213 supports burst data rates of up to

 

50 Kbytes per second for at least 512 bytes.

 

 

 

 

 

 