• OutputSwitch

When this is set to on, Arpeggio playback data is output from the MIDI terminal.

Settings on, off

• TransmitCh

Determines the MIDI transmit channel for Arpeggio playback data.

Settings 1 ~ 16

[F4] Common Controller Assign

The controllers and knobs on the front panel can be used to change and adjust a variety of parameters — in real time, and simultaneously.

For example, you could use the ASSIGN 1 and 2 knobs to control effect depth for two different effects, while using the Foot Controller to control modulation. These control assignments are called “Controller Assign.” You can have independent Controller Assign settings for each performance.

Set the Control Change number for the Breath Controller.

The function set here can be controlled by the Breath Controller connected to the BREATH CONTROLLER (page 28) jacks on the rear panel.

Determines the Control

Determines the Control Change numbers

Change numbers for the

for Foot Controllers 1 and 2. To control

ASSIGN 1 and 2 knobs

these functions, connect Foot Controllers

on the front panel.

to the FOOT CONTROLLER jacks on the

 

rear panel (page 28).

Settings (See chart below)

Control Change Numbers

 

LCD

 

LCD

00

off

32

off

 

 

 

 

01

ModWheel

64

Sustain

 

 

 

 

02

Breath

65

PortaSw

04

FootCtrl

66

Sostenut

 

 

 

 

05

PortTime

67

Soft

 

 

 

 

06

Data Ent

72

Release

07

MainVol

74

Bright

 

 

 

 

10

Panpot

75

Decay

 

 

 

 

11

Express

84

PortaCtl

16

General 1

91

Effect 1

 

 

 

 

17

General 2

92

Effect 2

 

 

 

 

18

General 3

93

Effect 3

19

General 4

 

 

 

 

 

 

Performance Edit mode

[F6]-[SF1] Common Effect Connection

Basic Structure (page 40)

This display gives you comprehensive control over the effects.

• EF PART (Effect part) VCE INS (VoiceInsertion)

Determines the part to which the Insertion effect is applied. The Insertion connection type (page 40) depends on the voice of the selected part.

Settings Part 1 ~ 4, Plug-in Part 1 ~ 3, off

• EF PART (Effect part) PLG-EF (Plug-inEfect)

Determines the part to which the Insertion effect is applied. This parameter is available only when a special Effect Plug-in board (VH) has been installed.

Settings Part 1~4, Plug-in Part 1~3, A/D, off

• Variation Type

Determines the Variation effect type.

Settings Refer to the Effect Types list in the separate Data List booklet.

• Variation Return

mode

Determines the Return level of the Variation Effect.

 

Settings

0 ~ 127

Performance

• Variation Pan

 

Determines the pan position of the Variation effect sound.

 

Settings

L64 (far left) ~cnt (center) ~ R63 (far

Reference

 

right)

 

 

• Variation To Reverb

 

Determines the Send level of the signal sent from the

 

Variation Effect to the Reverb Effect.

 

Settings

0 ~ 127

 

• Variation To Chorus

 

Determines the Send level of the signal sent from the

 

Variation Effect to the Chorus Effect.

 

Settings

0 ~ 127

 

• Chorus Type

 

Determines the Chorus effect type.

 

Settings

Refer to the Effect Types list in the separate

 

 

Data List booklet.

 

• Chorus Return Level)

Determines the Return level of the Chorus Effect. Settings 0 ~ 127

• Chorus Pan

Determines the pan position of the Chorus effect sound. Settings L64 (far left) ~ cnt (center) ~ R63 (far right)

MOTIF Reference 169