Utility mode

• Freq (Frequency)

Set the center frequency. Frequencies around this point are attenuated/boosted by the Gain setting.

Settings LOW (Low range) Peaking

63Hz ~ 2.0kHz

Shelving

32Hz ~ 2.0kHz

LOW MID (Low middle range) 100Hz~10kHz

MID (Middle range)100Hz~10kHz HIGH MID (High middle range) 100Hz ~10kHz

HIGH (High range)500Hz~16kHz

• Gain

Determines the level gain for the Frequency (set above), or the amount the selected frequency band is attenuated or boosted.

Settings -12dB~0dB~+12dB

Q (Frequency Characteristic)

This varies the signal level at the Frequency setting to create various frequency curve characteristics.

Settings 0.1~12.0

[F3]-[SF2] Voice Arpeggio Channel

From this display you can set parameters related to output of the Arpeggio MIDI data.

• OutputSwitch

This enables or disables MIDI data output for the Arpeggio function. When this is set to “on,” Arpeggio data is sent via MIDI — allowing you to send the Arpeggio data to an external sequencer or play back the Arpeggios on connected MIDI tone generators.

Settings

on (enable), off (disable)

• TransmitCh (Transmit channel)

Determines the MIDI channel through which Arpeggio playback data will be sent (when Output Switch above is on).

Settings 1~16

[F3]-[SF3] Voice Controller Assign

Reference

Sets the parameters related to the controllers in the

 

 

Voice mode.

 

 

Details about each parameter are same as in

Utility

Performance Common Edit. See page 169 .

Knob Assign 1, 2

Foot Controller 1, 2

mode

 

 

Breath Controller

Settings off, 0~95

[F3] Sequencer settings

These special song- and pattern-related settings are available only when entering the Utility mode from the Song or Pattern mode.

[F3]-[SF1] Sequencer Click (MIDI Click)

From this display you can set the parameters related to the click sound (metronome) that is used during recording or playback in the Song/Pattern mode.

• Mode

Determines whether and when the metronome click will sound.

Settings

off, rec, rec/play, all

off

The click will not sound.

rec

The click will sound during recording only.

rec/play

The click will sound during recording and playback.

all

The click will always sound.

• Beat

Determines on which beats the metronome click will sound.

Settings 16 (16th notes), 08 (8th notes), 04 (quarter notes), 02 (half notes), 01 (whole notes)

• Volume

Determines the click sound volume.

Settings 0~127

Rec Count

Sets the number of count-in measures provided before actually recording starts after pressing the [F] button in the Record standby mode .

Settings off (Recording starts as soon as the [F] button is pressed ), 1meas~8meas

nSince the click sound is created with the internal tone generator, using click playback affects the overall polyphony of the MOTIF.

254MOTIF Reference