Testing Performance

To test the threshold accuracy

Test the + User threshold

1Move the cursor to the field to the right of Pod 1. Type +6.00, then use the left and right cursor control keys to highlight V. Press the Select key.

2On the function generator front panel, enter +6.282 V ±1 mV DC offset. Use the multimeter to verify the voltage.

The activity indicators for pod 1 should show all data channels and the J-clock channel at a logic high.

3Using the Modify down arrow on the function generator, decrease offset voltage in 1-mV increments until all activity indicators for pod 1 show the channels at a logic low. Record the function generator voltage in the performance test record.

4Using the Modify up arrow on the function generator, increase offset voltage in

1-mV increments until all activity indicators for pod 1 show the channels at a logic high. Record the function generator voltage in the performance test record.

3–14

Page 36
Image 36
Agilent Technologies 01664-97005 manual Test the + User threshold