Testing Performance

To test the time interval accuracy

3Set up the function generator according to the following table.

Function Generator Setup

Freq: 200 000 . 0 Hz

Main Function: Square wave

Amptd: 3.000 V

High Voltage: Disabled (LED Off)

Phase: 0.0 deg

 

DC Offset: 0.0 V

 

Set up the logic analyzer

1Set up the Configuration menu. a Press the Config key.

b In the Configuration menu, assign Pod 1 to Machine 1. To assign Pod 1, select the Pod 1 field, then select Machine 1.

c In the Analyzer 1 box, select the Type field, then select Timing.

3–55

Page 77
Image 77
Agilent Technologies 01664-97005 manual To test the time interval accuracy, Function Generator Setup