NOTE

NOTE

Local Terminal Configuration

Using a Local Terminal

The probe CONFIG button is recessed. This requires the use of a narrow, pointed object (like a pen) to press the CONFIG button.

The probe executes a cold start if you press the CONFIG button twice within one second. If this happens, wait for the cold start to be completed and press the CONFIG button again to enter the configuration mode.

A warm start or cold start is completed when the Fault LED goes off. If traffic is present, the Activity LED flashes to show traffic.

Main Menu - Revision

1.Modify/View configuration values ->

2.Modify/View security values ->

3.Modify/View interface values ->

4.Display interface summary

5.TFTP Download new firmware ->

6.XMODEM Download new firmware ->

7.Warm start and Exit

8.Cold start and Exit

Figure 2-2: The Probe’s Main Menu

Item 5 in Figure 2-2 is not displayed if the Allow TFTP firmware downloads menu item is not enabled. Refer to “Modify/View Security Values” on page 24 for more information on enabling this menu item.

If item 5 (TFTP Download new firmware) is not displayed, the number used to access items 6, 7, and 8 will be different.