Agilent Technologies J3972A, J3919A manual OC-3 ATM Interface Configuration

Models: J3919A J3972A

1 189
Download 189 pages 36.38 Kb
Page 53
Image 53

Local Terminal Configuration

Using a Local Terminal

OC-3 ATM Interface Configuration

You must configure two of the three ports on the probe’s OC-3 ATM interface. The third port cannot be configured. Use the following procedure to configure items in the Modify/View Interface Values menu for the first port on the OC-3 ATM interface:

1.Press 3 to access the Modify/View interface values menu item. The Modify/View Interface Values menu for port 1 is displayed, as shown in Figure 2-7.

Modify/View Interface Values Menu - Firmware Rev

Interface Type

STS3C/STM1

1.

Port

3.1/STS3C-STM1

2.

Port Type

Monitor-only

3.

Cell Sychronization

HEC

4.

Cell Scrambling

On

S. Save changes and exit

 

0.

Cancel changes and exit

 

Figure 2-7: Modify/View Interface Values Menu (OC-3 ATM, Port 1)

2.Select each field requiring configuration (one at a time) by pressing its corresponding number and then entering the values that are appropriate for your network.

Port

Press 1 and then enter the OC-3 ATM interface’s port number

 

to display the OC-3 ATM port’s configuration parameters

 

along with their current settings. Refer to “Display Interface

 

Summary” on page 36 for information on port types and port

 

numbers for the installed interfaces. You can then view or

 

configure the OC-3 ATM port’s configuration parameters.

Port Type

Press 2 and select the port type as Monitor-only.

33

Page 53
Image 53
Agilent Technologies J3972A, J3919A OC-3 ATM Interface Configuration, Modify/View Interface Values Menu OC-3 ATM, Port